![DFE SteadyWeb Instruction Manual Download Page 66](http://html1.mh-extra.com/html/dfe/steadyweb/steadyweb_instruction-manual_2490682066.webp)
58
Appendix C:
Basic Set Up Sequence
This section of the instruction manual is provided for those cases in which many DIP switches or
potentiometer settings may have been changed and it is reasonable to assume that nothing is set
correctly. In order to get the controller operating properly perform the set-up in the sequence given
below. This is the sequence we use at Dover Flexo Electronics. For the sake of clarity, the actual set-
up steps are not repeated here because they are located elsewhere in this book. Their locations are
stated after the set-up step descriptions.
1. Turn Off the AC power to the controller.
2. Remove the cover. Lift the front panel to expose the circuit boards.
(Section 2.1)
3. Set the DIP switches on the Control board.
(Appendix B, Sections 5 and 6)
4. Set the power voltage selection switch on the Power board.
(Section 5.3)
5. Set the DIP switches on the Power board.
(Appendix B, Sections 5 and 6)
6. Set the transducer voltage selection switch on the Power board.
(Section 5.22)
7. Turn On the AC power to the controller and check the power supplies. Refer to Figure 17, the
Power Board. LEDs LD208 and LD209 should be lighted. Push the Power switch on the front panel
to apply power to the controller circuits. LEDs LD205 and LD206 should be lighted. These four
LEDs indicate the proper operation of the +/-15 volt DC power supplies. At this point, LED LD207
(+5VDC) and either the LD211 (5 volt) or LD212 (10 volt) transducer power LED should also be
lighted. Push the AUTO/MANUAL button on the front panel to verify operation of the AUTO and
MAN LEDs on the front panel.
8. Calibrate the tension meter.
(Section 4)
9. Adjust the Meter Correlation pot.
(Section 5.8)
10. Calibrate the 4-20mA tension output.
(Section 5.5)
11. Select the control voltage.
(Section 5.4)
12. Set up the output module.
(Section 5.7 High Voltage output, Version 12V)
(Section 5.12 Pneumatic output, Version 12P)
(No additional setup required for 0-10V output, Version 12D)
Summary of Contents for SteadyWeb
Page 1: ...INSTRUCTION MANUAL STEADYWEB AUTOMATIC TENSION CONTROLLER DOC 801 0783...
Page 8: ......
Page 10: ...2 1 2 STEADYWEB CONTROLLER EXPLODED VIEW Figure 1 STEADYWEB CONTROLLER EXPLODED VIEW...
Page 16: ...8 1 6 FRONT PANEL AND OPERATOR DEVICES Figure 2 FRONT PANEL and OPERATOR DEVICES...
Page 20: ...12 2 3 ELECTRICAL CONNECTIONS OF OPTIONS Figure 7 ELECTRICAL CONNECTIONS OF OPTIONS...
Page 29: ...21 5 1 THE CONTROL BOARD Figure 16 CONTROL BOARD...
Page 30: ...22 5 2 THE POWER BOARD Figure 17 POWER BOARD...
Page 56: ...48 Figure 39 TLS RELAY CONNECTIONS...
Page 70: ...62 Appendix F Transducer Electrical Connections Figure 45 MODELS C RS UPB TRANSDUCER WIRING...
Page 71: ...63 Figure 46 MODEL RFA VNW TRANSDUCER WIRING...
Page 72: ...64 Figure 47 MODELS TR NWI TRANSDUCER WIRING...