26
5.7 HIGH VOLTAGE OUTPUT MODULE
(SteadyWeb Version 12V only, description on Page 1)
This module, called the V-OUT card, contains the SCR bridge and driver circuitry to produce the
output voltage of the controller. It is designed to operate with either 115v or 230v input power and to
produce 90vdc, 45vdc, 24vdc, or 180vdc outputs. (The 180 volt output requires 230vac input.)
Figure 20
- V-OUT MODULE
a) To select the input and output voltages, set the SW401 switches as follows:
SW401 SWITCHES
0-90VDC Out
115VAC In
0-45VDC Out
115VAC In
0-24VDC Out
115VAC In
0-90VDC Out
230VAC In
0-45VDC Out
230VAC In
1 - Open
1 - Open
1 - Closed
1 - Open
1 - Closed
2 - Closed
2 - Closed
2 - Open
2 - Closed
2 - Open
3 - Open
3 - Open
3 - Open
3 - Open
3 - Open
4 - Open
4 - Closed
4 - Closed
4 - Closed
4 - Closed
0-24VDC Out
<-- THIS INPUT/OUTPUT IS FACTORY
0-180VDC Out
230VAC In
<-- INSTALLED
230VAC In
1 - Open
1 - Open
2 - Closed
Component changes and additions are
2 - Closed
3 - Open
required!
3 - Open
4 - Open
4 - Open
The SPAN and OFFSET pots.(RT401 and RT402) are set at the factory and should not require any
adjustment. If their settings have been changed, reset them as follows.
Summary of Contents for SteadyWeb
Page 1: ...INSTRUCTION MANUAL STEADYWEB AUTOMATIC TENSION CONTROLLER DOC 801 0783...
Page 8: ......
Page 10: ...2 1 2 STEADYWEB CONTROLLER EXPLODED VIEW Figure 1 STEADYWEB CONTROLLER EXPLODED VIEW...
Page 16: ...8 1 6 FRONT PANEL AND OPERATOR DEVICES Figure 2 FRONT PANEL and OPERATOR DEVICES...
Page 20: ...12 2 3 ELECTRICAL CONNECTIONS OF OPTIONS Figure 7 ELECTRICAL CONNECTIONS OF OPTIONS...
Page 29: ...21 5 1 THE CONTROL BOARD Figure 16 CONTROL BOARD...
Page 30: ...22 5 2 THE POWER BOARD Figure 17 POWER BOARD...
Page 56: ...48 Figure 39 TLS RELAY CONNECTIONS...
Page 70: ...62 Appendix F Transducer Electrical Connections Figure 45 MODELS C RS UPB TRANSDUCER WIRING...
Page 71: ...63 Figure 46 MODEL RFA VNW TRANSDUCER WIRING...
Page 72: ...64 Figure 47 MODELS TR NWI TRANSDUCER WIRING...