![DFE SteadyWeb Instruction Manual Download Page 49](http://html1.mh-extra.com/html/dfe/steadyweb/steadyweb_instruction-manual_2490682049.webp)
41
Figure 30
- PULSE TACH OPTION CARD
b) Be sure the pulse tachs are connected to Power board terminal strip as shown below.
Figure 31
- PULSE TACHOMETER CONNECTIONS
WARNING!! To prevent possible damage to the circuit card, set the SW601 switches as
shown below BEFORE installing the card and BEFORE running the machine!
INITIAL SW601 SETTINGS
1 - Closed
2 - Open
3 - Open
4 - Closed
c) Determine the maximum pulse amplitude of pulses from the LTACH and the RTACH pulse tachs.
The data sheet that came with them should give this data or allow you to calculate it. The
amplitude can also be measured using an oscilloscope. Set the SW601 switches according to the
maximum amplitude using the chart below.
SW601 SWITCHES
RTACH
LTACH
Pulse Amplitude (volts)
1
2
3
4
.25 - 2.0
Open
Closed
Closed
Open
1.0 - 50.0
Closed
Open
Open
Closed
Summary of Contents for SteadyWeb
Page 1: ...INSTRUCTION MANUAL STEADYWEB AUTOMATIC TENSION CONTROLLER DOC 801 0783...
Page 8: ......
Page 10: ...2 1 2 STEADYWEB CONTROLLER EXPLODED VIEW Figure 1 STEADYWEB CONTROLLER EXPLODED VIEW...
Page 16: ...8 1 6 FRONT PANEL AND OPERATOR DEVICES Figure 2 FRONT PANEL and OPERATOR DEVICES...
Page 20: ...12 2 3 ELECTRICAL CONNECTIONS OF OPTIONS Figure 7 ELECTRICAL CONNECTIONS OF OPTIONS...
Page 29: ...21 5 1 THE CONTROL BOARD Figure 16 CONTROL BOARD...
Page 30: ...22 5 2 THE POWER BOARD Figure 17 POWER BOARD...
Page 56: ...48 Figure 39 TLS RELAY CONNECTIONS...
Page 70: ...62 Appendix F Transducer Electrical Connections Figure 45 MODELS C RS UPB TRANSDUCER WIRING...
Page 71: ...63 Figure 46 MODEL RFA VNW TRANSDUCER WIRING...
Page 72: ...64 Figure 47 MODELS TR NWI TRANSDUCER WIRING...