33
3. Actuation by machine speed.
This requires an optional DC Tachometer card or Pulse Tachometer card to provide a
machine speed signal. Calibrate the card as described in Section 6 before proceeding with
Soft Start set-up.
a) Set the
SW104
switches as follows:
SW104
1 - Open
2 - NA
3 - NA
4 - NA
b) Set the SS OUTPUT pot.(RT107) for the output you want while in Soft Start. The range is about
0 to 100% of maximum output. Turn the pot. CW to increase output. Avoid setting the output
higher than the operating tension. It is best to set it low, but high enough to produce enough
tension to exceed the trip point tension or the controller may not be able to get out of Soft Start.
c) Set the SS LINE TRIP pot. (RT111) to the machine speed at which you want to actuate Soft
Start. The range is about 0 to 100% of maximum line speed. Turn the pot. CW to increase the
actuation speed. Set the pot. to about 5%. Do NOT leave it at 0 or Soft Start will be active all
the time.
d) Set the SS LINE DLY pot. (RT116) for a short time delay before Soft Start actuates. This
eliminates nuisance actuation if machine speed hovers around the trip point. The range is about
0 to 3 seconds. Turn the pot. CW to increase the delay. There is no delay when leaving the
Soft Start mode.
e) Set the SS TEN TRIP pot. fully CCW to avoid interference with the SS LINE TRIP pot.
5.19 SPEED FOLLOW (See Page 5 for description, Figure 16 for switch)
The SW101 switches must be set to indicate the use or nonuse of the Speed Follow function. Set the
switches as in the following table:
SW101 SWITCH
1
2
3
4
Speed Follow function OFF
NA
NA
NA
Open
Speed Follow function ON
NA
NA
NA
Closed
Nip roll speed signal OFF
NA
NA
Open
NA
Nip roll speed signal ON
NA
NA
Closed
NA
NA = Not Applicable
Summary of Contents for SteadyWeb
Page 1: ...INSTRUCTION MANUAL STEADYWEB AUTOMATIC TENSION CONTROLLER DOC 801 0783...
Page 8: ......
Page 10: ...2 1 2 STEADYWEB CONTROLLER EXPLODED VIEW Figure 1 STEADYWEB CONTROLLER EXPLODED VIEW...
Page 16: ...8 1 6 FRONT PANEL AND OPERATOR DEVICES Figure 2 FRONT PANEL and OPERATOR DEVICES...
Page 20: ...12 2 3 ELECTRICAL CONNECTIONS OF OPTIONS Figure 7 ELECTRICAL CONNECTIONS OF OPTIONS...
Page 29: ...21 5 1 THE CONTROL BOARD Figure 16 CONTROL BOARD...
Page 30: ...22 5 2 THE POWER BOARD Figure 17 POWER BOARD...
Page 56: ...48 Figure 39 TLS RELAY CONNECTIONS...
Page 70: ...62 Appendix F Transducer Electrical Connections Figure 45 MODELS C RS UPB TRANSDUCER WIRING...
Page 71: ...63 Figure 46 MODEL RFA VNW TRANSDUCER WIRING...
Page 72: ...64 Figure 47 MODELS TR NWI TRANSDUCER WIRING...