1.3 SPECIFICATIONS
POWER INPUT
12P and 12D . . . . .
120/240 Volts 60/50Hz single phase @ 1 Amp
12V
. . . . . . . . . . . .
120/240 Volts 60/50Hz single phase @ 5 Amp
OUTPUT
12P
. . . . . . . . . . . .
0.5 to 75 psi (,03 to 5,17 bar)
12V
. . . . . . . . . . . .
90 Volts DC, 45 VDC, 24 VDC, all @ 4 Amp
. . . . . . . . . . . .
180VDC @4 Amp and 230VAC Input
12D . . . . . . . . . . . .
0-10 Volts DC, compensated and isolated
TENSION SIGNAL OUTPUT . . . . . . . . . .
0-10 Volts DC
. . . . . . . . . . .
4-20 MA into 500 ohm maximum load
ENCLOSURE
. . . . . . . . . . . .
Steel, powder resin painted, NEMA 1
WEIGHT
. . . . . . . . . . . .
26 lbs. (11,8 KG)
AIR CONNECTIONS:12P In . . . . . . . . . .
3/8 inch plastic tubing (5/16", 8mm optional)
Out . . . . . . . . .
1/4 inch plastic tubing (6mm)
INTERNAL AIR FILTER
12P . . . . . . . . .
5 micron, 1/2 pint bowl, automatic drain
TRANSDUCER SIGNAL
. . . . . . . . . . . .
500 mv DC per pair at rated load, 1.0 Volt with
. . . . . . . . . . .
Extended Range option
MATING TRANSDUCER CABLE
CONNECTORS
. . . . . . . . . . . .
Amphenol MS3106A-10SL-3S
ZERO (TARE) RANGE
. . . . . . . . . . . .
95% of transducer rating, minimum
CALIBRATION RANGE
. . . . . . . . . . . .
25:1
TEMPERATURE RANGE . . . . . . . . . . . .
32 to 104 deg.F (0-40 deg.C)
SYSTEM ACCURACY
. . . . . . . . . . . .
1 - 3% typical
TENSION METER
. . . . . . . . . . . .
Analog, 2%, 1ma, 48 ohm
OUTPUT RANGE
. . . . . . . . . . . .
0-100% Max., Min. = 0-20% of Max.
MANUAL MODE OUTPUT RANGE . . . . .
0-100%
OUTPUT RATIO RANGES . . . . . . . . . . .
1:10(multiplier) and 10:1(divider)
STANDARD TENSION METER SCALES
0 - 1,5,10,25,50,100,150,250,500,1000
TENSION LIMIT SWITCH RELAY
CONTACTS (option)
. . . . . . . . . . . .
SPDT rated @ 10A/30VDC, 10A/250VAC
TAPER TENSION RANGE (option) . . . . .
0-100%
TAPER TENSION INPUTS (option)
Code TTDCT (using DC Tachs) . . .
Switch selected, 3V to 250V
Code TTPT (using Pulse Tachs) . . .
300Hz to 40KHz at max. line speed
Code TTF (Roll Follower) . . . . . . . .
10K ohm pot. minimum
Code TTR (external voltage) . . . . . .
0-10VDC core to full roll
Summary of Contents for SteadyWeb
Page 1: ...INSTRUCTION MANUAL STEADYWEB AUTOMATIC TENSION CONTROLLER DOC 801 0783...
Page 8: ......
Page 10: ...2 1 2 STEADYWEB CONTROLLER EXPLODED VIEW Figure 1 STEADYWEB CONTROLLER EXPLODED VIEW...
Page 16: ...8 1 6 FRONT PANEL AND OPERATOR DEVICES Figure 2 FRONT PANEL and OPERATOR DEVICES...
Page 20: ...12 2 3 ELECTRICAL CONNECTIONS OF OPTIONS Figure 7 ELECTRICAL CONNECTIONS OF OPTIONS...
Page 29: ...21 5 1 THE CONTROL BOARD Figure 16 CONTROL BOARD...
Page 30: ...22 5 2 THE POWER BOARD Figure 17 POWER BOARD...
Page 56: ...48 Figure 39 TLS RELAY CONNECTIONS...
Page 70: ...62 Appendix F Transducer Electrical Connections Figure 45 MODELS C RS UPB TRANSDUCER WIRING...
Page 71: ...63 Figure 46 MODEL RFA VNW TRANSDUCER WIRING...
Page 72: ...64 Figure 47 MODELS TR NWI TRANSDUCER WIRING...