Caution!
For your own safety!
For drive systems incorporating a built-in battery backup system it is not simply
sufficient to pull out the mains plug! Due to
in the battery, the drive
can still start up even if the mains plug has been pulled out!
Removing the mechanical connections between the mounting and drive system before
the bed has been allowed to travel back to the horizontal starting position, presents a
and hence a
.
the closer, it is therefore essential to allow the bed to first travel back
to the
residual charge
mains plug
plug for the
battery backup system
trap risk
potential injury hazard
Before opening
horizontal starting position!
Therefore, in addition to pulling out the
, also pull out the
, as described on page 8.
9
c)
Dismantling
support the drive
opening the closer
closer re-engage
Loosen the screws, remove the cap and then the leads from the respective plug sockets.
Drive the application in basic position,
before
- once
these are open, the drive is released immediately!
Make sure that the