Dewert duomat 7 care l Installation Instructions Manual Download Page 20

20

9.

Cleaning

10.

Disposal

The

drive system has been designed to facilitate cleaning for the user, and this

has been made even easier thanks to the large number of flat surfaces.
The

drive system should be cleaned with a proprietary cleaning agent suitable for

using a damp cloth. Always note the instructions provided by the manufacturer of

the respective cleaning agent used.

the drive system in a wash tunnel or with a

. You risk damaging the equipment!

When

take care not to damage the drive system’s

!

The drive system only offers protection against spray water (classification IP44).

such as

,

or similar substances.

The

drive system contains electronic components, cables, metal, plastic etc.

:

DUOMAT 7

DUOMAT 7

polyamid 6

Never clean

high-pressure cleaner nor spray

liquids onto it

cleaning

mains connection lead

Do not use any solvents

benzene alcohol

DUOMAT 7

Before cleaning, always pull out the mains plug!

The

drive system should be disposed of in accordance with the environmental

regulations applicable in the respective country. Information on this subject can also be
obtained from

Federal Association for
Disposal Management BDE
Behrenstraße 29
D-10117 Berlin
Germany
Phone: +49 (0) 30-59 00 33 5-0
www.bde-berlin.de

are to be disposed of in line with the

.

DUOMAT 7

Accumulators

AltBattVO

Drive systems and accumulators may not be disposed of with
the normal household waste! (Ordinance on Disposal of Old Batteries).

Notes on environmental directives and legislation

"

"

The product is not subject to the European Directive 2002 / 96 / EC (WEEE) and its
amendment EU Directive 2003 / 108 / EC.

In as far as this product includes batteries, this complies with

the Battery Ordinance of 27th March 1998 (BGBI. I S.658)

"

The product complies with the European Directive 2002 / 95 / EC (RoHS as of
01.07.2006).

DUOMAT 7 CARE L/HOSP L

Summary of Contents for duomat 7 care l

Page 1: ...Installation Instructions for the of the End Product Manufacturer DUOMAT 7 Drive System CARE L HOSP L Issue 10 2007...

Page 2: ...are not designed for passing on to operator of the end product With regard to the specialist information contained herein these instructions can serve as a basis for drawing up the instructions for th...

Page 3: ...u are a or you should this work to suitably only Conformity according to EC Directives The drive system is supplied ex factory as a machine in accordance with the EC Machines Directive In other words...

Page 4: ...chanical loads Regular visual checks of the mains connection lead should be carried out at short term intervals and in particular each time it has been subjected to a mechanical load If the mains conn...

Page 5: ...Instructions apply to this product accordingly MEGAMAT MEGAMAT MEDIX CARE MEDIX HOSP MEDIX CARE SB SK SE SE Optional Locking device HOSP Supervisor HOSP SE First error security Function LED Function L...

Page 6: ...750 x 190 mm with Emergency Release Axle base 581 mm Weight approx 6 3 kg without battery backup system Voltage 2 x 12 VDC Capacity 1 2 Ah with new batteries Fuse T 15 A Battery type Lead battery Amb...

Page 7: ...set locking device supervisor battery back up unpacking not to damage the cable Caution the battery backup system contains a residual charge installation residual charge operate a Installation Applyin...

Page 8: ...he operator that if leads in particular the are they could sustain damage When routing the cables make sure that they cannot get entangled or trapped are not subjected to mechanical loads i e do not p...

Page 9: ...ence a the closer it is therefore essential to allow the bed to first travel back to the residual charge mains plug plug for the battery backup system trap risk potential injury hazard Before opening...

Page 10: ...again Futher informations see i a Prerequisites DUOMAT 7 battery backup system for emergency lowering at least 10 hours emergency lowering charged ready for operation The functions of provided t on t...

Page 11: ...rate the Emergency Release lever hold lever in this position fig below and lower the backrest legrest Depending on backrest legrest version it is possible that the backrest legrest could lower itself...

Page 12: ...r it this indicates an error The must then be immediately blocks or releases the adjustment keys The released state is indicated by the mode LED glowing Check the blocked adjustment keys mode LED does...

Page 13: ...ch Blocking is symbolized by a closed shackle lock Furthermore the locking device in the CARE L and HOSP L versions features up to 3 adjustment keys which by way of example depending on the version ca...

Page 14: ...isor allows the bed to be adjusted as well as the adjustment functions to be blocked The supervisor has been designed as a two hand control thereby making it impossible to actuate adjustment inadverte...

Page 15: ...using for cracks and fractures and the mains connection lead for signs of pinching and shearing off Also check the strain relief with kink protection in particular after each case of mechanical loadin...

Page 16: ...y specialist personnel holding the qualifications described on page 3 or by persons who have taken part and successfully completed the corresponding training programs offered by DEWERT After correctly...

Page 17: ...Seal Each drive component carries a type plate giving the exact designation item number and technical specifications for explanation see following figure as an example Graphical Symbols Conformity ma...

Page 18: ...handset Version depends on application range e g IPROXX DEWERT slave drive e g MEGAMAT DEWERT battery backup unit AG 7 attachable optional DUOMAT 7 dual drive QUADROMAT version Emergency Release mech...

Page 19: ...s constantly CARE HOSP only Permanent or longer CARE HOSP only sounding waring signal Drives suddenly no longer respond no movement takes place Handset or drive system without function Contact your su...

Page 20: ...lead Do not use any solvents benzene alcohol DUOMAT 7 Before cleaning always pull out the mains plug The drive system should be disposed of in accordance with the environmental regulations applicable...

Page 21: ...ormity with the above Directive of the entire machine into which it is to be installed has been declared Partially applied harmonized standards Safety of Machines Guiding Technical Principles Kirchlen...

Page 22: ...The Manufacturer meets the following EC Directives Applied Standards Constructional changes which affect the technical data stated in the Installation Instructions as well as the designated use in oth...

Page 23: ...ults cases EN60601 1 10 Constructional EN60601 1 56 8 Power supply indicator not available EN1970 in part section 4 Unintentional movement Prevention via blocking device e g Locking device or MEDIX SK...

Page 24: ...ility EN60601 2 38 52 4 Unintentional movement EN60601 2 38 52 5 9 Failure of subassemblies prevention via EN60601 2 38 52 5 101 Failure of electrical components EN60601 2 38 52 5 102 Tilting of the b...

Page 25: ...DEWERT Antriebs und Systemtechnik Weststra e 1 32278 Kirchlengern Germany Phone 49 0 5223 979 0 Fax 5223 75182 http www dewert de Info dewert de GmbH 49 0 ID No 43698...

Reviews: