65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 51 -
RDS/RBDS PAGE
All basic elements of the RDS/RBDS are displayed on the screen – PI, PS, RT, TA/TP and etc.
The Alternative frequencies are also available, represented as a list. The Open Data Applications
are left blank for further definition, by default. Only two of these ODA Groups are defined. At your
disposal are the Radio Text and the Traffic Message Channel.
If your Radio station has RT+ or TMC – Radio Explorer II will display the information from
the ODA Groups.
A BER Indicator with graphics is placed at the right bottom part of the screen, showing 60 sec.
history of the BER quantities.
NOTE:
The bit error rate or bit error ratio (BER) is the number of bit errors divided by the
total number of transferred bits during a studied time interval. Result closer or equal to 0 indicates
that no bit errors are detected and vice versa result closer or equal to 1 indicates that the received
transferred bits are only errors.
Total groups Indicator – all received groups are systematized into a table, representing the
percentage/quantity of the groups in the received RDS/RBDS signal. The user selects how the
“Total groups received” data should be displayed: as Percents (%) or Count, by selecting the
corresponding button.