15
Table 5 - Minimum clearances – combustible materials - CANADA
LOCATION
APPLICATION
CLEARANCE
(combustible materials)
RECOMMENDED ACCESS
FOR SERVICE
Left or right
0.6 m (24")
Sides
Left or right
0.25 mm (9")
Back
Access panel to blower
0.6 m (24")
0.9 m (36")
Furnace or plenum
0.15 m (6”)
Top
Horizontal warm air duct within 1.8 m (6') of
furnace
0.15 m (6”)
Bottom
Furnace (combustible floor)
0”
Horizontally or below flue pipe
0.25 mm (9")
Flue pipe
Vertically above flue pipe
0.25 mm (9")
Front
From burner
0.6 m (24")
*Refer to the applicable installation code if a clearance reduction is required ( ex: CSA B139 in Canada )
Table 6 - Minimum clearances – combustible materials -USA
LOCATION
APPLICATION
CLEARANCE
(combustible materials)
RECOMMANDED ACCESS
FOR SERVICE
Sides
Left or right
0.15 m (6”)
Back
Access panel to blower
0.15 m (6”)
0.9 m (36")
Top
Furnace or plenum
50.8 mm (2”)
Bottom
Furnace (combustible floor)
0”
Flue pipe
All around
0.5 m (18”)
Front
From burner
0.6 m (24")
*Refer to the applicable installation code if a clearance reduction is required ( ex: NFPA 31 in the USA )
*
*
*
*
*
Summary of Contents for AMT400B34-SM1PMA
Page 16: ...16 Figure 5 Furnace dimensions DNS 0848 Rev E...
Page 17: ...17 Figure 6 Ladder Diagram Heating and Cooling AMT400B34 SM1PMA OLR350H28B...
Page 18: ...18 Figure 7 Wiring Diagram heating and cooling AMT400B34 SM1PMA OLR350H28B DNS 1016 Rev B...
Page 19: ...19 Figure 8 Wiring Diagram Heating AMT400B34 SM1PMA OLR350H289B DNS 1021 Rev B...
Page 20: ...20 COMPONENTS AND REPLACEMENT PARTS...
Page 21: ...21 Figure 9 Parts List With 4 speed motor PSC B50043B...
Page 40: ...18 Figure 6 Diagramme en chelle chauffage et climatisation AMT400B34 SM1PMA OLR350H28B...
Page 42: ...20 Figure 8 Diagramme lectrique chauffage AMT400B34 SM1PMA OLR350H28 DNS 1021 Rev B...
Page 44: ...22 B50043 Rev B Figure 9 Liste de pi ces avec moteur 4 vitesses PSC...