MPS+1-AC
MPS+1-AC
Field of Application
The MPS+1-AC power supply unit
supplies power to the first six slots
(1 to 6) of the OpenCom 510. The
MPS+1-AC converts the output volt-
ages (220 V/110 V) output voltages
into a DC voltage (+3.3 V and
–
42 V).
If the remaining slots (7 to 12) are to
be used, a second MPS+1-AC power
supply unit will need to be installed.
MPS+1-AC: Front view
Technical Data
The following data refer to the sup-
ply of power to the first six slots.
MPS+1-AC
Input Voltage
Rated voltage
230 V via standard
IEC connector
Voltage range
95 V to 275 V
Rated current
2.0 A at 115 V
1.0 A at 230 V
0.9 A at 275 V
Efficiency at rated
load
> 80 %
+3.3 V Output Voltage
Rated voltage
+3.3 V
Voltage range
+3.2 V... +3.4 V
Rated current
10.0 A
Current limitation 12 A to 15 A
Short-circuit
Continuous short-
circuit protection
–
42 V Output Voltage
Rated voltage
–42 V
Voltage range
–40 V... –44 V