69
Modules
MS+A1-8
MS+A1-8
The LEDs indicate the following:
Operational Information
The MS+A1-8 interface card can be
exchanged during operation, i.e.
without powering down the system.
However, the slot must first be deac-
tivated in the
Configurator
in the
web console (see
a/b 1
a/b 2
MS+A1-8
1
2
3
4
LED 1: Constantly yellow
At least one connection established through the in-
terface card is active.
LED 2:
Constantly green
The interface card is operational; the slot has been
activated (flickering is normal).
Flashing yellow
The interface card is ready, but the slot has not been
activated or the interface card has not been config-
ured yet.
Constantly red
New software is being loaded onto the interface
card. If the LED lights up red for an extended period
of time, there may be a fault.
LED 3:
–
Not used
LED 4:
–
Not used