background image

104323

COMPACT CLASSIC HEARTH FIREPLACE

VMH26PR

18

®

 CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

 WARNING: Make sure the

selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Open window to vent smell. This
will only last a few hours.

OPERATING
FIREPLACE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: You must operate

this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.

1.

STOP! Read the safety information,
column 1.

2.

Make sure manual shutoff valve is
fully open.

3.

Set switch in OFF position.

 WARNING: Burner will come

on automatically within one
minute when the selector switch
is in the ON position after the
pilot is lit.

4.

Press in and turn control knob clock-
wise 

  to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

6.

Press in and turn control knob coun-
terclockwise  

  to the PILOT

position. Press in control knob for
five (5) seconds (see Figure 35).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 19.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

 If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise 

 to the

ON position.

10. Wait one minute and switch selector

switch to the ON position to light
burner.

11. Set flame adjustment knob to any

level between HI and LO.

Figure 35 - Control Knob and Ignitor Button Location (Shown as Supplied,
No Control Options)

O

F

F

PI

LOT O

N

LO

IH

AUTO
OFF
ON

Control Knob

Ignitor Button

Selector
Switch in
OFF Position

Flame
Adjustment
Knob

Summary of Contents for Vanguard VMH26PR

Page 1: ...t Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury or p...

Page 2: ...cool before touching 18 Carefully supervise young children when they are in same room with fire place 19 Do not use fireplace if any part has been under water Immediately call a quali fied service te...

Page 3: ...hipping damage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The...

Page 4: ...ges 26 and 27 Install op tional blower now Follow installation instructions provided with blower 5 Gently place back log on burner sup port see Figure 2 The log should fit flat against top of burner s...

Page 5: ...in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere...

Page 6: ...__________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the act...

Page 7: ...Crawl Space To Attic AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adj...

Page 8: ...UTION This fireplace cre ateswarmaircurrents Thesecur rents move heat to wall surfaces next to fireplace Installing fire place next to vinyl or cloth wall coverings or operating fireplace where impuri...

Page 9: ...ight 26 26 7 8 Front Width 26 3 4 26 7 8 Depth 9 1 2 10 1 2 Bottom 3 4 3 4 1 Frame in rough opening Use dimen sions shown in Figure 8 for the rough opening If installing in a corner use dimensions sho...

Page 10: ...on wood base 3 Place mantel around fireplace base as sembly 4 Assemble brass trim kit See Assem bling Brass Trim 5 Firmly snap brass trim kit on shoulder screws Shoulder screws are located on fireplac...

Page 11: ...of valve cover shield 2 Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly 3 Note the wire locations on back of AUTO OFF ON switch The terminals on back of...

Page 12: ...e box cover to secure the wiring Wir ing should be routed through the bushing in the hole on the outer casing of heater 1 Install a snap bushing found in hard ware kit into one of the holes found rear...

Page 13: ...ing base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Thehardwarepack age is provided with fireplace 1 Drill holes at marked locations using 5 16 dri...

Page 14: ...he fireplace The flexible gas supply line con nection to the manual shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line...

Page 15: ...k for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig u...

Page 16: ...should be done by a quali fied installer familiar with low voltage wiring procedures INSTALLATION Continued OPTIONAL WIRELESS HAND HELD REMOTE CONTROL ACCESSORIES GHRC Series GHRCT Series Installing...

Page 17: ...t wire to bottom contact of switch see Figure32 2 Connect remaining wire terminal to the TH terminal on the control valve Make sure that wire terminals are in the positions on your unit as pictured in...

Page 18: ...screen in place Make sure fire place screen is installed before running fireplace 1 STOP Read the safety information column 1 2 Make sure manual shutoff valve is fully open 3 Set switch in OFF positio...

Page 19: ...structions on page 18 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjust ment knob anywhere between HI and LO Slide the selector switch to...

Page 20: ...page 17 of this manual IMPORTANT The hand held remote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermostat on the hand held re mot...

Page 21: ...ct Burner Flame Pattern Figure43 IncorrectBurnerFlamePattern WARNING If yellow tipping occurs your fireplace could pro duce increased levels of carbon monoxide If burner flame pat tern shows yellow ti...

Page 22: ...aged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind b...

Page 23: ...Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clea...

Page 24: ...produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor d...

Page 25: ...air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500 hours of operation or every three months Wealsorecommendthatyoukeepth...

Page 26: ...o stain or paint Complete assembly instructions in cluded Three sided brass trim kit included CABINET MANTEL WITH BUILT IN HEARTH BASE AND TRADITIONAL SQUARE LEG STYLING Unfinished GM923U Finished GM9...

Page 27: ...ed under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Technical Service Department at 1 800 323 5...

Page 28: ...SIC HEARTH FIREPLACE VMH26PR 28 ILLUSTRATED PARTS BREAKDOWN VMH26PR 39 37 38 22 40 11 28 30 12 7 35 25 10 4 9 7 23 1 2 8 4 4 14 6 24 33 34 31 32 13 17 21 5 26 18 15 27 1 27 2 41 41 41 41 3 29 16 18 17...

Page 29: ...1 Baffle 1 24 101628 01 Flexible Connector 1 25 104305 01 Control Shield 1 26 103295 01CJ Screen Assembly 1 27 103058 01 Log Set Assembly 1 27 1 104058 01 Branch Service Kit 1 27 2 104058 02 Back Log...

Page 30: ...cts caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO T...

Reviews: