25

104323

OWNER’S MANUAL

CLEANING AND
MAINTENANCE

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

 WARNING: Turn off fireplace

and let cool before cleaning.

 CAUTION: You must keep con-

trol areas, burner, and circulating
air passageways of fireplace clean.
Inspect these areas of fireplace
before each use. Have fireplace
inspected yearly by a qualified
service person. Fireplace may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.

You can also visit DESA International’s
Technical Services web site at

www.desatech.com.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• fireplace will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

WIRING DIAGRAM

Switch

Black

Auto

Off
On

Red

Red

White

Thermopile

Gas Control 

TPTH

TH

TPTH TP

CLEANING BURNER
INJECTOR HOLDER AND
PILOT AIR INLET HOLE

The primary air inlet holes allow the proper
amount of air to mix with the gas. This
provides a clean burning flame. Keep these
holes clear of dust, dirt, and lint. Clean these
air inlet holes prior to each heating season.
Blocked air holes will create soot. We rec-
ommend that you clean the unit every 2,500
hours of operation or every three months.

We also recommend that you keep the burner
tube and pilot assembly clean and free of
dust and dirt. To clean these parts we recom-
mend using compressed air no greater than
30 PSI. Your local computer store, hard-
ware store, or home center may carry com-
pressed air in a can. You can use a vacuum
cleaner in the blow position. If using com-
pressed air in a can, please follow the direc-
tions on the can. If you don't follow direc-
tions on the can, you could damage the pilot
assembly.

1.

Shut off the unit, including the pilot.
Allow the unit to cool for at least thirty
minutes.

2.

Inspect burner, pilot, and primary air
inlet holes on injector holder for dust
and dirt (see Figure 44).

3.

Blow air through the ports/slots and
holes in the burner.

Figure 44 - Injector Holder On Outlet
Burner Tube

4.

Check the injector holder located at the
end of the burner tube again. Remove
any large particles of dust, dirt, lint, or
pet hairs with a soft cloth or vacuum
cleaner nozzle.

5.

Blow air into the primary air holes on
the injector holder.

6.

In case any large clumps of dust have
now been pushed into the burner repeat
steps 3 and 4.

Clean the pilot assembly also. A yellow tip
on the pilot flame indicates dust and dirt in
the pilot assembly. There is a small pilot air
inlet hole about two inches from where the
pilot flame comes out of the pilot assembly
(see Figure 45). With the unit off, lightly
blow air through the air inlet hole. You may
blow through a drinking straw if compressed
air is not available.

Burner
Tube

Injector Holder

Primary Air Inlet
Holes

Figure 45 - Pilot Inlet Air Hole

Pilot Assembly

Pilot Air Inlet
Hole

Ports/Slots

Summary of Contents for Vanguard VMH26PR

Page 1: ...t Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury or p...

Page 2: ...cool before touching 18 Carefully supervise young children when they are in same room with fire place 19 Do not use fireplace if any part has been under water Immediately call a quali fied service te...

Page 3: ...hipping damage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensor Shutoff System ODS The...

Page 4: ...ges 26 and 27 Install op tional blower now Follow installation instructions provided with blower 5 Gently place back log on burner sup port see Figure 2 The log should fit flat against top of burner s...

Page 5: ...in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere...

Page 6: ...__________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the act...

Page 7: ...Crawl Space To Attic AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adj...

Page 8: ...UTION This fireplace cre ateswarmaircurrents Thesecur rents move heat to wall surfaces next to fireplace Installing fire place next to vinyl or cloth wall coverings or operating fireplace where impuri...

Page 9: ...ight 26 26 7 8 Front Width 26 3 4 26 7 8 Depth 9 1 2 10 1 2 Bottom 3 4 3 4 1 Frame in rough opening Use dimen sions shown in Figure 8 for the rough opening If installing in a corner use dimensions sho...

Page 10: ...on wood base 3 Place mantel around fireplace base as sembly 4 Assemble brass trim kit See Assem bling Brass Trim 5 Firmly snap brass trim kit on shoulder screws Shoulder screws are located on fireplac...

Page 11: ...of valve cover shield 2 Make sure the wire harness is firmly connected to the terminals on the blower bracket assembly 3 Note the wire locations on back of AUTO OFF ON switch The terminals on back of...

Page 12: ...e box cover to secure the wiring Wir ing should be routed through the bushing in the hole on the outer casing of heater 1 Install a snap bushing found in hard ware kit into one of the holes found rear...

Page 13: ...ing base to solid floors concrete or masonry Note Floor anchors and mounting screws areinhardwarepackage Thehardwarepack age is provided with fireplace 1 Drill holes at marked locations using 5 16 dri...

Page 14: ...he fireplace The flexible gas supply line con nection to the manual shutoff valve should be accessible 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line...

Page 15: ...k for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig u...

Page 16: ...should be done by a quali fied installer familiar with low voltage wiring procedures INSTALLATION Continued OPTIONAL WIRELESS HAND HELD REMOTE CONTROL ACCESSORIES GHRC Series GHRCT Series Installing...

Page 17: ...t wire to bottom contact of switch see Figure32 2 Connect remaining wire terminal to the TH terminal on the control valve Make sure that wire terminals are in the positions on your unit as pictured in...

Page 18: ...screen in place Make sure fire place screen is installed before running fireplace 1 STOP Read the safety information column 1 2 Make sure manual shutoff valve is fully open 3 Set switch in OFF positio...

Page 19: ...structions on page 18 1 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjust ment knob anywhere between HI and LO Slide the selector switch to...

Page 20: ...page 17 of this manual IMPORTANT The hand held remote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermostat on the hand held re mot...

Page 21: ...ct Burner Flame Pattern Figure43 IncorrectBurnerFlamePattern WARNING If yellow tipping occurs your fireplace could pro duce increased levels of carbon monoxide If burner flame pat tern shows yellow ti...

Page 22: ...aged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind b...

Page 23: ...Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clea...

Page 24: ...produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor d...

Page 25: ...air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500 hours of operation or every three months Wealsorecommendthatyoukeepth...

Page 26: ...o stain or paint Complete assembly instructions in cluded Three sided brass trim kit included CABINET MANTEL WITH BUILT IN HEARTH BASE AND TRADITIONAL SQUARE LEG STYLING Unfinished GM923U Finished GM9...

Page 27: ...ed under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA International s Technical Service Department at 1 800 323 5...