reqUireMentS FOr the cOMMOnWeALth OF 

MASSAchUSettS

For all side wall horizontally vented gas fueled 

equipment installed in every dwelling, building or 
structure used in whole or in part for residential 
purposes, including those owned or operated by 
the Commonwealth and where the side wall ex-

haust vent termination is less than seven (7) feet 
above finished grade in the area of the venting, 

including but not limited to decks and porches, 

the following requirements shall be satisfied:

INSTALLATION OF CARBON 
MONOXIDE DETECTORS

At the time of installation of the side wall horizon

-

tal vented gas fueled equipment, the installing 

plumber  or  gasfitter  shall  observe  that  a  hard 

wired carbon monoxide detector with an alarm 

and battery backup is installed on the floor level 

where the gas equipment is to be installed. In 

addition, the installing plumber or gasfitter shall 

observe that a battery operated or hard wired car-
bon monoxide detector with an alarm is installed 
on each additional level of the dwelling, building or 

structure served by the side wall horizontal vented 

gas fueled equipment. It shall be the responsibility 
of the property owner to secure the services of 

qualified licensed professionals for the installation 

of hard wired carbon monoxide detectors.

In  the  event  that  the  side  wall  horizontally 

vented  gas  fueled  equipment  is  installed 
in a crawl space or an attic, the hard wired 
carbon  monoxide  detector  with  alarm  and 
battery back-up may be installed on the next 

adjacent floor level.

In  the  event  that  the  requirements  of  this 
subdivision  can  not  be  met  at  the  time  of 
completion  of  installation,  the  owner  shall 

have a period of thirty (30) days to comply with 
the above requirements; provided, however, 
that during said thirty (30) day period, a battery 

operated carbon monoxide detector with an 
alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required 
in accordance with the above provisions shall 
comply with NFPA 720 and be ANSI/UL 2034 

listed and IAS certified.

SIGNAGE

A metal or plastic identification plate shall be 

permanently  mounted  to  the  exterior  of  the 

building at a minimum height of eight (8) feet 

above grade directly in line with the exhaust 

vent terminal for the horizontally vented gas 

fueled heating appliance or equipment. The 

sign shall read, in print size no less than 1/2" in 
size, "GAS VENT DIRECTLY BELOW. KEEP 

CLEAR OF ALL OBSTRUCTIONS".

INSpECTION

The state or local gas inspector of the side 

wall horizontally vented gas fueled equipment 

shall not approve the installation unless, upon 
inspection,  the  inspector  observes  carbon 
monoxide detectors and signage installed in 
accordance with the provisions of 248 CMR 

5.08(2)(a) 1 through 4.

EXEMPTIONS: The following equipment is ex-

empt from 248 CMR 5.08(2)(a) 1 through 4:
•  The equipment listed in Chapter 10 entitled 

"Equipment  Not  Required To  Be  Vented" 
in the most current edition of NFPA 54 as 

adopted by the Board; and

•  Product Approved  side  wall  horizontally 

vented gas fueled equipment installed in a 
room or structure separate from the dwell-
ing, building or structure used in whole or 
in part for residential purposes.

MANUFACTURER REqUIREMENTS

Gas Equipment Venting System Provided 

When the manufacturer of Product Approved 

side wall horizontally vented gas equipment 

provides a venting system design or venting 
system components with the equipment, the 
instructions provided by the manufacturer for 
installation of the equipment and the venting 
system shall include:

•  Detailed instructions for the installation of 

the venting system design or the venting 

system components; and

•  A complete parts list for the venting system 

design or venting system.

Gas Equipment Venting System Not 

provided

When  the  manufacturer  of  a  Product Ap-

proved side wall horizontally vented gas fu

-

eled equipment does not provide the parts for 

venting the flue gases, but identifies "special 

venting systems", the following requirements 

shall be satisfied by the manufacturer:
• 

The referenced "special venting system" in-
structions shall be included with the appliance 

or equipment installation instructions; and

•  The "special venting systems" shall be Prod

-

uct Approved by the Board, and the instruc-
tions for that system shall include a parts list 
and detailed installation instructions.

A  copy  of  all  installation  instructions  for  all 

Product  Approved  side  wall  horizontally 

vented gas fueled equipment, all venting in-
structions,  all  parts  lists  for  venting  instruc-
tions,  and/or  all  venting  design  instructions 
shall remain with the appliance or equipment 
at the completion of the installation.

Summary of Contents for IRONHAUS Yellowstone IDVF36HN

Page 1: ...ierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer serv...

Page 2: ...ful home 1 Inspect your enclosure and fireplace unit for any damage Contact your dealer and or shipper immediately if damaged and document with photos etc 2 Remove handcrafted face and mesh door and s...

Page 3: ...horizontal and vertical installation This fireplace complies with the National Safety Standards This fireplace must be installed by a qualified certified or licensed service person It brings in fresh...

Page 4: ...ected annually by a qualified service person 5 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint and dust from ca...

Page 5: ...in the way of the venting system Choose a location where the heat output is not affected by drafts air conditioning ducts windows or doors Figure 2 shows some common locations Be aware of all restrict...

Page 6: ...or other materials 0 clear ance to combustible materials are for framing purpose only NOTICE Thisfireplaceisintend edforuseassupplementalheat Use this fireplace along with your primary heating system...

Page 7: ...30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m hori...

Page 8: ...ade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY B...

Page 9: ...vent pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burnin...

Page 10: ...with special twist lock con nections Twist Lock Procedure Female ends of pipes have locking lugs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pi...

Page 11: ...rior wall with provided wood screws see Figure 11 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe bef...

Page 12: ...with critical minimum and maximum dimensions which MUST be met NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward a...

Page 13: ...If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space...

Page 14: ...18 shows the configurations for vertical termination Venting Installation Continued Figure 18 Vertical Venting Configuration Vertical Venting V 40 max High Altitude Installation Your DESA Heating LLC...

Page 15: ...Air Flex Vent Kit CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fireplace See retailer where you purchased the fireplace...

Page 16: ...g equipment shutoff valve to fireplaces Figure 20 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down Fireplace Installation Co...

Page 17: ...ff valve was connected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas fireplace or opening main gas valve located on or near gas meter for natural...

Page 18: ...to Appliance page 22 Removing Replacing Glass Doors CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel securely in place For replacement part informa tion...

Page 19: ...ddle Bottom Brick Right Bottom Brick Glass Door Lava Rock Ember Flakes and Scrap Log Installation Lava rock ember flakes and scrap log pieces are included with your fireplace Install these items while...

Page 20: ...Once battery is activated the unit is ready to use 5 Replace center brick control cover Figure 32 Installing Battery into Back of Handset Battery Cover Back of Handset Fireplace Installation Continue...

Page 21: ...fety information col umn 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position 4 Remove center brick control cover 5 Turn equipment shutoff valve clockwise to t...

Page 22: ...OPERATION 1 Turn equipment shutoff valve to ON posi tion You can now turn the burner on and off with hand held remote control unit IMPORTANT Be sure to press ON OFF buttons on hand held remote contro...

Page 23: ...rasive cleaners as this may damage glass Use a nonabra sive household glass cleaner to clean glass Do not clean glass when hot Glass must be cleaned periodically During start up it is normal for conde...

Page 24: ...l inspection of the venting system following these guidelines 1 Check areas of venting system that are exposed to the weather for corrosion rust spots or streaks and in extreme cases holes Have these...

Page 25: ...cktoseeifyouhavegas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts appliance does not light call...

Page 26: ...n or cor roded 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum flame im pingement on thermopile 2 Have vent system inspect ed including termination cap Remove any restrictio...

Page 27: ...ame holes blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glas...

Page 28: ...www ironhaus com or www desatech com 123129 01A 28 Parts Models IDVF36SN IDVF36SP IDVF36HN IDVF36HP 10 14 9 7 21 11 32 23 24 26 25 2 8 22 15 16 17 18 19 33 34 20 30 13 1 3 4 12 6 5 27 31 29 28...

Page 29: ...1 Air Exchange 1 15 Top Insulation 1 16 120261 01 Fireplace Top 1 17 23490SA Fireplace Top Spacer 4 18 120243 01 8 Outer Pipe 1 19 111554 05 5 Inner Connector 1 20 106702 01 5 Gasket 1 21 120431 01 Bu...

Page 30: ...desatech com 123129 01A 30 Parts Burner Assembly Models IDVF36SHN IDVF36SHP IDVF36SN IDVF36SP IDVF36HN IDVF36HP 23 1 22 32 36 17 16 18 2 19 6 20 12 13 11 37 37 7 10 9 19 14 28 8 5 3 4 15 27 21 25 24...

Page 31: ...rass T Fitting 1 21 111817 06 Flextube 3 8 x 11 1 22 Burner Base Gasket 1 23 Firebox Bottom 1 24 111817 08 Flextube 3 8 x 18 1 25 120454 01 Valve Ignition Assembly 1 26 11105 Hex Screw 30 27 114365 15...

Page 32: ...www ironhaus com or www desatech com 123129 01A 32 Parts Refractory parts Models IDVF 36SN IDVF 36SP IDVF 36HN IDVF 36HP 14 20 15 19 17 13 11 6 8 4 2 1 9 5 9 1 3 7 11 12 16 18 18 22 21 10...

Page 33: ...182 01 Rear Refractory Bracket 1 11 120149 01 Refractory Housing 8 12 120148 03 Top Left Side Refractory 1 13 120148 02 Top Right Side Refractory 1 14 120148 01 Side Refractory 6 15 120146 01 Bottom L...

Page 34: ...040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to th...

Page 35: ...hase Transit damage and results from alterations are not covered by this warranty IRONHAUS disclaims all other warranties whether expressed or implied and specifically disclaims the implied warranties...

Page 36: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: