Keep  the  area  around  your 

fireplace  clear  of  combustible 

materials,  gasoline  and  other 

flammable vapor or liquids. Do 

not  run  fireplace  where  these 

are used or stored.

1.  For  propane/LP  fireplace,  do  not  place 

propane/LP  supply  tank(s)  inside  any 

structure.  Locate  propane/LP  supply 

tank(s) outdoors. To prevent performance 

problems, do not use propane/LP fuel tank 
of less than 100 lb. capacity.

2.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a  neighbor’s  phone.  Follow  the  gas 
supplier's instructions

• if you cannot reach you gas supplier, call 

the fire department.

3.  Never install the fireplace

• in a recreational vehicle
• in windy or drafty areas where curtains or 

other combustible (flammable) objects can 
make contact with the fireplace front

• in high traffic areas

4.  Turn  fireplace  off  and  let  cool  before 

servicing,  installing  or  repairing.  Only  a 

qualified  service  person  should  install, 

SAFety

Continued

Figure 1 - Direct Vent Fireplace

Log Set

Flue Collar

Nailing Flange

Standard 
Brick 
Refractories

Andiron

service or repair this fireplace. Have fire

-

place  inspected  annually  by  a  qualified 

service person.

5.  You  must  keep  control  compartments, 

burners  and  circulating  air  passages 
clean.  More  frequent  cleaning  may  be 
needed  due  to  excessive  lint  and  dust 
from  carpeting,  bedding  material,  etc. 
Turn off the gas valve and pilot light before 

cleaning fireplace.

6.  Have venting system inspected annually by 

a qualified service person. If needed, have 

venting system cleaned or repaired. See 

Cleaning and Maintenance

, page 23.

7.  Do not use any solid fuels (wood, coal, 

paper,  cardboard,  etc.)  in  this  fireplace. 
Use only the gas type indicated on fire

-

place nameplate.

8.  This appliance, when installed, must be 

electrically grounded in accordance with 
local  codes  or,  in  the  absence  of  local 
codes, with the 

National Electrical Code, 

ANSI/NFPA 70.

9.  Do not use fireplace if any part has been 

exposed to or under water. Immediately 

call a qualified service person to arrange 

for replacement of the unit.

10. 

Do not operate fireplace if any log is broken.

11. Do not operate fireplace with glass door 

removed, cracked or broken.

12. Provide adequate clearances around air 

openings.

LOcAL cODeS

Install and use fireplace with care. Follow all 

local  codes. In the absence  to local  codes, 
use the current 

National Fuel Gas Code ANSI 

Z223.1/NFPA 54*

 (USA).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park, 

Quincy, MA 02269

PrODUct 

iDentiFicAtiOn

Summary of Contents for IRONHAUS Yellowstone IDVF36HN

Page 1: ...ierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer serv...

Page 2: ...ful home 1 Inspect your enclosure and fireplace unit for any damage Contact your dealer and or shipper immediately if damaged and document with photos etc 2 Remove handcrafted face and mesh door and s...

Page 3: ...horizontal and vertical installation This fireplace complies with the National Safety Standards This fireplace must be installed by a qualified certified or licensed service person It brings in fresh...

Page 4: ...ected annually by a qualified service person 5 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint and dust from ca...

Page 5: ...in the way of the venting system Choose a location where the heat output is not affected by drafts air conditioning ducts windows or doors Figure 2 shows some common locations Be aware of all restrict...

Page 6: ...or other materials 0 clear ance to combustible materials are for framing purpose only NOTICE Thisfireplaceisintend edforuseassupplementalheat Use this fireplace along with your primary heating system...

Page 7: ...30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m hori...

Page 8: ...ade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY B...

Page 9: ...vent pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burnin...

Page 10: ...with special twist lock con nections Twist Lock Procedure Female ends of pipes have locking lugs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pi...

Page 11: ...rior wall with provided wood screws see Figure 11 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe bef...

Page 12: ...with critical minimum and maximum dimensions which MUST be met NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward a...

Page 13: ...If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space...

Page 14: ...18 shows the configurations for vertical termination Venting Installation Continued Figure 18 Vertical Venting Configuration Vertical Venting V 40 max High Altitude Installation Your DESA Heating LLC...

Page 15: ...Air Flex Vent Kit CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fireplace See retailer where you purchased the fireplace...

Page 16: ...g equipment shutoff valve to fireplaces Figure 20 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down Fireplace Installation Co...

Page 17: ...ff valve was connected 3 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas fireplace or opening main gas valve located on or near gas meter for natural...

Page 18: ...to Appliance page 22 Removing Replacing Glass Doors CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass door panel securely in place For replacement part informa tion...

Page 19: ...ddle Bottom Brick Right Bottom Brick Glass Door Lava Rock Ember Flakes and Scrap Log Installation Lava rock ember flakes and scrap log pieces are included with your fireplace Install these items while...

Page 20: ...Once battery is activated the unit is ready to use 5 Replace center brick control cover Figure 32 Installing Battery into Back of Handset Battery Cover Back of Handset Fireplace Installation Continue...

Page 21: ...fety information col umn 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position 4 Remove center brick control cover 5 Turn equipment shutoff valve clockwise to t...

Page 22: ...OPERATION 1 Turn equipment shutoff valve to ON posi tion You can now turn the burner on and off with hand held remote control unit IMPORTANT Be sure to press ON OFF buttons on hand held remote contro...

Page 23: ...rasive cleaners as this may damage glass Use a nonabra sive household glass cleaner to clean glass Do not clean glass when hot Glass must be cleaned periodically During start up it is normal for conde...

Page 24: ...l inspection of the venting system following these guidelines 1 Check areas of venting system that are exposed to the weather for corrosion rust spots or streaks and in extreme cases holes Have these...

Page 25: ...cktoseeifyouhavegas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after re peated attempts appliance does not light call...

Page 26: ...n or cor roded 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum flame im pingement on thermopile 2 Have vent system inspect ed including termination cap Remove any restrictio...

Page 27: ...ame holes blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glas...

Page 28: ...www ironhaus com or www desatech com 123129 01A 28 Parts Models IDVF36SN IDVF36SP IDVF36HN IDVF36HP 10 14 9 7 21 11 32 23 24 26 25 2 8 22 15 16 17 18 19 33 34 20 30 13 1 3 4 12 6 5 27 31 29 28...

Page 29: ...1 Air Exchange 1 15 Top Insulation 1 16 120261 01 Fireplace Top 1 17 23490SA Fireplace Top Spacer 4 18 120243 01 8 Outer Pipe 1 19 111554 05 5 Inner Connector 1 20 106702 01 5 Gasket 1 21 120431 01 Bu...

Page 30: ...desatech com 123129 01A 30 Parts Burner Assembly Models IDVF36SHN IDVF36SHP IDVF36SN IDVF36SP IDVF36HN IDVF36HP 23 1 22 32 36 17 16 18 2 19 6 20 12 13 11 37 37 7 10 9 19 14 28 8 5 3 4 15 27 21 25 24...

Page 31: ...rass T Fitting 1 21 111817 06 Flextube 3 8 x 11 1 22 Burner Base Gasket 1 23 Firebox Bottom 1 24 111817 08 Flextube 3 8 x 18 1 25 120454 01 Valve Ignition Assembly 1 26 11105 Hex Screw 30 27 114365 15...

Page 32: ...www ironhaus com or www desatech com 123129 01A 32 Parts Refractory parts Models IDVF 36SN IDVF 36SP IDVF 36HN IDVF 36HP 14 20 15 19 17 13 11 6 8 4 2 1 9 5 9 1 3 7 11 12 16 18 18 22 21 10...

Page 33: ...182 01 Rear Refractory Bracket 1 11 120149 01 Refractory Housing 8 12 120148 03 Top Left Side Refractory 1 13 120148 02 Top Right Side Refractory 1 14 120148 01 Side Refractory 6 15 120146 01 Bottom L...

Page 34: ...040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to th...

Page 35: ...hase Transit damage and results from alterations are not covered by this warranty IRONHAUS disclaims all other warranties whether expressed or implied and specifically disclaims the implied warranties...

Page 36: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: