Dentsply Sirona
Operating Instructions inLab Profire
3 Technical description
3.5 Technical data
67 15 887 D3770
D3770.201.01.02.02 05.2019
13
3.5
Technical data
Model designation:
inLab Profire
Version
Zirconia only
13 A
Zi metal
13 A
Zirconia only
15 A
Zi metal
15 A
Type of protection against elec-
tric shock:
Class I (PE-connected)
Protection type:
IP 20
(Protection against the ingress of foreign bodies, but not against the ingress of
water)
Setup:
Indoors in dry area
Height
up to 3,000 m
Temperature range:
5°C to 40°C (41°F to 104°F)
Relative humidity
80% to 31°C (87.8°F), linearly decreasing above this
up to 50% at 40°C (104°F), no condensation
Setup conditions:
100 mm minimum distance to the unit
Overvoltage category:
Overvoltage category II
Pollution degree:
2
Mode of operation
Continuous operation
Dimensions of unit (W x H x D):
360 mm x 780 mm x 534 mm
Packaging dimensions (W x H
x D):
720 mm x 1300 mm x 620 mm
Furnace chamber (diameter x
height in mm):
2 trays ⌀120 mm
x 30 mm
1x sintering bell
jar system
2 trays ⌀120 mm
x 30 mm
1x sintering bell
jar system
Maximum sintering tempera-
ture:
1,650°C
(3,002°F)
1,400°C
(2,552°F)
1,650°C
(3,002°F)
1,400°C
(2,552°F)
Approx. weight without packag-
ing:
64 kg
Approx. weight including pack-
aging:
80 kg
Optimum input pressure range
for argon supply:
7+/-1 bar
Maximum input pressure range
for argon supply:
10 bar
Rated line voltage:
220 V~ to 230 V~
200 V~ to 240 V~
Rated power frequency:
50 Hz
50/60 Hz
Maximum power consumption:
3,500 W
Unit-based fuse:
16 AT
On-site fuse:
Connection to a separate electrical circuit with a 16 A fuse, type K, Z (other
fuse types according to the country of use)