61 30 608 D3497
D3497
.
076.01.09
.
02 10.2018
47
Dentsply Sirona
10 Upgrading
Service Manual inFire HTC speed
10.1 Upgrading to Superspeed
båÖäáëÜ
For super speed sintering, the furnace must be preheated to operating
temperature 1,580°C / 2,876°F After preheating (approximately 32 mins),
the user has a time window available of 30 mins in which the Superspeed
cycle can be activated.
If the user does not take any action by the end of this time slot, the furnace
will switch off again.
The exact program sequence can be viewed in the following diagram.
Progra
m No.
Program designation
Preheating time + cycle time
(until door opening)
Furnace type
01
Sirona inCoris TZI/ZI super speed single
30 mins + 10.8 mins
220 V, 16 A, 50 Hz
47 mins + 11.2 mins
220 V, 13 A, 50 Hz =
GB version
72 mins + 15.8 mins
180 V, 16 A, 60 Hz