61 30 608 D3497
24
D3497
.
076.01.09
.
02 10.2018
8 Troubleshooting
Dentsply Sirona
8.2 Error without message on the display
Service Manual inFire HTC speed
8.2.3
Error: LED on control panel indicates heating, but furnace
does not heat
Cause
Heating defective.
Elimination
Check whether heating is jammed, measure resistance with ohmmeter:
R
o.k.
= 0.6 Ω
individual heating element = 0.1 Ω
Replace defective heating element (see "Replacing the heating element
[ → 29]“).
Call customer service.
Cause
Controller board defective.
Elimination
Replace controller board (see "Replacing the controller board [ → 30]“).
Call customer service.