Do not disassemble or alter the device; Dentsply Maillefer declines any responsibility in
case of alteration or modification of the device.
•
Do not expose the X-SMART
™
Plus unit, motor handpiece or AC adapter to any liquid.
•
Do not drop the device.
•
The X-SMART
™
Plus requires special precautions as regards electromagnetic compatibility
(EMC) and must be installed and commissioned in strict conformity with the EMC
information provided in this instruction manual. Specifically, do not use the device close to
fluorescent lamps, radio transmitters and remote controls.
•
In order to avoid possible risks due to electromagnetic interference, do not use any
electrical medical device or electrical device of any other kind in close proximity to the X-
SMART
™
Plus. The electromagnetic radiation emitted by the device is below the
recommended limits set forth in pertinent regulations in force (EN 60601-1-2:2007).
•
Do not use the device in the presence of free oxygen or anesthetic substances or
flammable products.
•
The device may possibly malfunction if used in the presence of an electromagnetic
interference wave. Do not install the X-SMART
™
Plus in the vicinity of any device that emits
magnetic waves.
•
The use of accessories, transducers and cables other than those specified may result in
increased emissions or decreased immunity performance of the device.
•
None of the X-SMART
™
Plus components are delivered disinfected or sterilized:
components such as control unit, micromotor and micromotor cable need to be disinfected,
the contra-angle needs to be sterilized prior to first use and in between each patient!
•
Never place the motor handpiece or any other device accessories in an autoclave unit or
ultrasonic tank.
•
None of the components of the X-SMART
™
Plus may be sterilized (contra-angle excluded,
see chapter 6.12. Cleaning, Disinfection and Sterilization).
•
Do not immerse the device in ultrasonic cleaners.
•
The plastic enclosure is not sealed, do not use any liquid or spray directly on the unit,
especially on the monitor or near the electrical sockets.
•
Do not crimp the cords exiting the motor handpiece and AC adapter.
•
This device is equipped with an electronic circuit to limit file separation. Nevertheless, files
may still separate due to incorrectly set torque or speed, or the use of fatigued files.
•
Follow the file manufacturer’s instructions for use of the endodontic files.
•
The file system shown on the display must always match the file in use. This is of the
utmost importance in order to avoid misusing reciprocating files and continuous rotary files.
•
Do not use files designed for continuous rotation in reciprocating motion.
•
Do not use files designed for reciprocating motion in continuous rotation.
•
Torque and speed values are subject to change by the file manufacturers without notice.
Therefore, the preset values in the library must be checked prior to use. Torque values
shown on the screen are accurate and reliable only with X-SMART
™
Plus 6:1 contra-angles
properly maintained and lubricated.
•
The accuracy of movement provided by the motor is guaranteed only if the original X-
SMART
™
Plus 6:1 contra-angle is used, properly maintained and lubricated (for more
details see chapter 6.11.2. Lubricating the Contra-angle).
Summary of Contents for X-SMART Plus
Page 1: ...USER MANUAL...
Page 3: ...FISDR JAP F1902124 X 00 2011 created 07 2011 4 208...
Page 83: ...FISDR JAP F1902124 X 00 2011 created 07 2011 84 208...
Page 163: ...FISDR JAP F1902124 X 00 2011 created 07 2011 164 208...
Page 207: ...FISDR JAP F1902124 X 00 2011 created 07 2011 208 208...
Page 208: ...FISDR JAP F1902124 X 00 2011 created 07 2011 209 208...