81
Chapter 3. Communications Operations of BHT-5000
(2)
Text control characters
The text control characters are used to format transmission texts. In the BHT-protocol,
they include the following headers and a terminator.
Symbol
Value
Meaning
Function
SOH
01h
Start Of Heading
Indicates the start of heading text (Phase
2).
STX
02h
Start Of Text
Indicates the start of data text (Phase 2).
ETX
03h
End Of Text
Indicates the end of data text (Phase 2).
You may designate headers and a terminator by the protocol functions in BHT-BASIC
3.0. If you designate none of them in a user program, the BHT-5000 may apply those
as listed above. Refer to the "BHT-BASIC 3.0 Programmer's Manual."