Chapter 2. Getting Started the BHT-5000 and System Mode
[4.5]
Setting the communications parameters and interface port
After the BHT-5000 is initialized, the communications parameters and the interface
port to be used are set as listed in the default table below. Do not access them unless
necessary.
Communications parameters
Defaults
Transmission speed
19,200 bps
Character length
8 bits
Parity
None
Stop bits
1 bit
Protocol
Serial number ON:
Adds serial numbers
to data blocks.
Horizontal parity ON:
Adds a horizontal
parity.
RS/CS control OFF:
Disables the RS/CS
control.
Timeout:
30 seconds
Last space:
Ignore
Interface port
Optical interface port
SET COMMUNICATION
1:Optical
2:Connector
3:Default
Selecting "5: Communication" on the SET SYS-
TEM menu calls up the screen shown at left.
1 Optical
:
Shifts to the parameter/protocol
selection screen
for the optical in-
terface. (The CU-5000 is required.)
2 Connector :
Shifts to the parameter/protocol
selection screen
for the direct-con-
nect interface.
3 Default
:
Shifts to the interface port setting
screen.
Select a desired screen by using the numerical
keys or
* and
* keys, and then press ENT
key.
To return to the SET SYSTEM menu, press C key.
* For BHT-5000s having a 26-key pad, use F5 and F6 keys instead of
and
keys,
respectively