smartDEN
IP-Maxi
User Manual
09 Mar 2018
- 14 -
3. Technical parameters
Table 3.1.
Physical parameters
Parameter
Value
Size (L / W / H), mm
210 x 85 x 58
Weight, g
420
Operating temperature, °C
0 to 70
Table 3.2.
System parameters
Parameter
Value
Power supply voltage, V DC
12 or 24 (depends on the model)
±2
Maximum current consumption, mA
450 at 12V, 300 at 24V
Protection against reverse polarity
Yes
Hardware Real Time Clock (RTC)
Yes
Default settings restore button
Yes
Reset button
Yes
Table 3.3.
Digital inputs
Parameter
Value
Digital inputs number
8
Digital inputs voltage range, V DC
0 up to 30
Input switching threshold from 0 to 1, V DC
> 7.6
Input switching threshold from 0 to 1, mA
> 3.2
Input switching threshold from 1 to 0, V DC
< 4.5
Input switching threshold from 1 to 0, mA
< 1.8
Supported sensor output type
PNP
Input type
Resistive with Schmitt trigger
Protection against reverse polarity
Yes
Table 3.4.
Counters
Parameter
Value
Counters number
8
Max. pulses frequency
Digital Inputs 1, 2, 3 1 ..10 Hz (
Digital Inputs 4, 5, 6,
7
9 kHz
Digital Input 8
40 kHz