smartDEN
IP-Maxi
User Manual
09 Mar 2018
- 60 -
Table 9.4
.
Relays
Start OID
End OID
Description
Access Syntax
x.
8.2.3.1.2.0
x.
8.2.3.1.2.7
Relay Description
R/W
DisplayString (SIZE(0..7))
x.
8.2.3.1.3.0
x.
8.2.3.1.3.7
Relay Working Mode
R/W
Integer {Multiple(0),Regulator(1)}
x.
8.2.3.1.4.0
x.
8.2.3.1.4.7
Relay
← Digital Input No
R/W
Integer (0..8)
x.
8.2.3.1.5.0
x.
8.2.3.1.5.7
Relay
← Digital Input Mode
R/W
Integer (0..7)
x.
8.2.3.1.6.0
x.
8.2.3.1.6.7
Relay ← Analog Input (+) No
R/W
Integer (0..8)
x.
8.2.3.1.7.0
x.
8.2.3.1.7.7
Relay ← Analog Input (-) No
R/W
Integer (0..8)
x.
8.2.3.1.8.0
x.
8.2.3.1.8.7
Relay ← Analog Threshold 1
R/W
Integer (-9999..9999)
x.
8.2.3.1.9.0
x.
8.2.3.1.9.7
Relay ← Analog Threshold 2
R/W
Integer (-9999..9999)
x.
8.2.3.1.10.0
x.
8.2.3.1.10.7 Relay Disable Week Schedule
R/W
Integer { No(0), Yes(1) }
x.
8.2.3.1.11.0
x.
8.2.3.1.11.7 Relay Set Pulse Period
R/W
Integer32 (0..65535)
x.
8.2.3.1.12.0
x.
8.2.3.1.12.7 Relay Start Pulse
R/W
Integer32 (0..65535)
x.
8.2.3.1.13.0
x.
8.2.3.1.13.7 Relay State
R/W
Integer {Off(0), On(1), Toggle(2)}
x.
8.2.3.1.14.0
x.
8.2.3.1.14.7 Relay Use Filter
R/W
Integer { No(0), Yes(1) }
x.
8.2.3.1.15.0
x.
8.2.3.1.15.7 Relay Filter, ms
R/W
Integer (0..9999)
Table 9.5.
Analog Outputs
Start OID
End OID
Description
Access Syntax
x.
8.2.4.1.2.0
x.
8.2.4.1.2.1
Analog Output Description
R/W
DisplayString (SIZE(0..7))
x.
8.2.4.1.3.0
x.
8.2.4.1.3.1
Analog Output Units
R/W
Integer (0..1023)
9.1.3.
Control
Table 9.6
.
Control
OID
Description
Access Syntax
x.
8.3.1.0
TemperatureScale
R/W
Integer {Celsius(0), Fahrenheit(1) }
x.
8.3.2.0
AnalogInputFilter
R/W
Integer (0..30)
x.
8.3.3.0
RelayFilter
R/W
Integer (0..9999)
x.
8.3.4.0
Digital Inputs State
R
Integer (0..255)
x.
8.3.5.0
Relays State
R/W
Integer (0..255)
x.
8.3.6.0
System Date (dd/mm/yyyy)
R/W
DisplayString
x.
8.3.7.0
System Time (hh:mm)
R/W
DisplayString
x.
8.3.8.0
Reboot smartDEN IP-Maxi
R/W
Integer (0..255)
x.
8.3.9.0
sysUpTime
R
TimeTicks
To reboot the device via SNMP, set the Reboot value to the ASCII code of the
first char of your Web password. For example, if this is the char 'a', the code
in decimal is 97.
9.1.4.
Traps
Table 9.7
.
Traps
OID
Description
Access Syntax
x.
8.4.1.0
Trap Enable Flag
R/W
Integer { No(0),Yes(1) }
x.
8.4.2.0
Trap Receiver IP Address
R/W
IpAddress
x.
8.4.3.0
Trap Receiver Port
R/W
Integer32 (0..65535)
x.
8.4.4.0
Community in Sending Trap
R/W
DisplayString (SIZE (0..7))
x.
8.4.5.0
Trap Sending Mode
R/W
Integer { Level(0), Edge(1) }
x.
8.4.6.0
System UpTime
R
TimeTicks