19
Removing and Replacing the Grip (Figure 11)
The Grip (9015) can be used in two
positions so that when the gripping teeth
show signs of wear, it may be reversed to
extend the life of the part. Loosen the Grip
Retaining Clip Screw (9024) and swing the
Grip Retaining Clip (9023) out of the way.
Remove the Grip and reverse its position
within the Grip Holder. If both edges are
worn, replace the part. Return the Grip
Retaining Clip to its original position and
tighten the Grip Retaining Clip Screw.
Figure 11 - Replacing the Grip
Removing and Replacing the Tension Pawl (Figure 12)
The Tension Pawl (9098) is double-ended so that when
one end is worn, it can be reversed, increasing the life of
the part by providing a new gripping surface. To remove
the Tension Pawl, disengage the Tension Pawl Spring
(9134) from the Tension Pawl and remove the Wire
Straightener Roll Clip (9124). Flip the Tension Pawl over
so that a new surface is in contact with Wire Straightener
Roller (9103) and replace the E-clip. Make sure that the
Tension Pawl is under the flange in the Wire Straightener
Roll before re-engaging the Tension Pawl Spring. If both
sides of the Pawl are worn, replace the part.
Figure 12 - Replacing the Tension Pawl
!
Always disconnect the power supply before
assembling the StitchMaster or making any adjustments.
CAUTION
!
9024
9015
9023
9103
9098
9124
9134