Chapter 4 Parameters
VFD-EL-W
4-59
For example, to activate MI3 and MI4, set Pr.04.28 to 12.
The delay function of multi-function input terminals ON/OFF: In the testing process of automatic production
line, the conveyor uses photoelectric switch as a triggered switch for the position reached, which means the
conveyor stops once the product arrives the specified position. However, there may be a difference between
the installation position of the photoelectric switch and the specified position the product arrives. Therefore,
this delay time function is added for the convenience of tuning.
04.29
Delay Time of Multi-function Input Terminal (MI1) Turn On
Settings
0.00–360.00 sec.
Default: 0.00
04.30
Delay Time of Multi-function Input Terminal (MI1) Turn Off
Settings
0.00–360.00 sec.
Default: 0.00
04.31
Delay Time of Multi-function Input Terminal (MI2) Turn On
Settings
0.00–360.00 sec.
Default: 0.00
04.32
Delay Time of Multi-function Input Terminal (MI2) Turn Off
Settings
0.00–360.00 sec.
Default: 0.00
04.33
Delay Time of Multi-function Input Terminal (MI3) Turn On
Settings
0.00–360.00 sec.
Default: 0.00
04.34
Delay Time of Multi-function Input Terminal (MI3) Turn Off
Settings
0.00–360.00 sec.
Default: 0.00
Summary of Contents for VFD-EL-W Series
Page 7: ...v This page intentionally left blank ...
Page 21: ...Chapter 1 Introduction VFD EL W 1 14 This page intentionally left blank ...
Page 34: ...Chapter 2 Installation and Wiring VFD EL W 2 13 This page intentionally left blank ...
Page 42: ...Chapter 3 Keypad and Start up VFD EL W 3 8 This page intentionally left blank ...
Page 150: ...Chapter 4 Parameters VFD EL W 4 108 This page intentionally left blank ...
Page 152: ...Chapter 5 Troubleshooting VFD EL W 5 2 5 1 Over Current oc ...
Page 153: ...Chapter 5 Troubleshooting VFD EL W 5 3 5 2 Over Voltage ov ...
Page 154: ...Chapter 5 Troubleshooting VFD EL W 5 4 5 3 Low Voltage Lv ...
Page 155: ...Chapter 5 Troubleshooting VFD EL W 5 5 5 4 Overheat oH1 ...
Page 156: ...Chapter 5 Troubleshooting VFD EL W 5 6 5 5 Overload oL ...
Page 157: ...Chapter 5 Troubleshooting VFD EL W 5 7 5 6 Keypad Display is Abnormal 5 7 Phase Loss PHL ...
Page 158: ...Chapter 5 Troubleshooting VFD EL W 5 8 5 8 Motor Does Not Run ...
Page 159: ...Chapter 5 Troubleshooting VFD EL W 5 9 5 9 Motor Speed Cannot be Changed ...
Page 163: ...Chapter 5 Troubleshooting VFD EL W 5 13 This page intentionally left blank ...
Page 179: ...Appendix A Specifications VFD EL W A 6 This page intentionally left blank ...