Delta Electronics. Inc.
HPH-
20KA01KAT
10
3.4.
Process and Monitor Function
Table 3.4 Adjustable function parameters for User
Item
Specification
Description
Max. Power
2 to 20 kW
Power will be constrained within
the value of setting prior to the
set point of regulation.
Max. Current
5 to 50 A
Current will be constrained
within the value of setting prior
to the set point of regulation.
Max. Voltage
500 to 1000 V
Voltage will be constrained
within the value of setting prior
to the set point of regulation.
Ignition Mechanism
1000 to 1900
V
A voltage up to 1900 V is
adjustable for igniting the
system.
Ramp Time
50 to 2000 ms
A ramp up to set point is
adjustable for a soft start
mechanism.
Set Point
1 to 10 s
Monitoring if the output reaches
the setting of regulation within
the setting of period.
Energy Mode
1 to 99999 kJ
Monitoring if the output energy
reaches the setting of energy.
Target Life Mode
1 to 15000 kWh
Monitoring if the output energy
reaches the setting of kWh.
3.5.
Mechanical Specification
The outward appearance, cooling specification for minimum CFM Requirement, and I/O ports
of Delta “HPH-20KA01KAT” power supply are described as below:
Table 3.5 Mechanical specification
Item
Description
Physical Dimension
482.6 mm (W) x 132.5 mm (H) x 600 mm (L)
19" (W) x 5.2" (H) x 22.0" (L)
19" 3U
Weight
38.7 kg
Cooling
Fan cooling
Noise
Noise generated by this unit under 70 dB (A) at a 1m distance in 25
˚C ambient temperature
AC Input Connector
4 pin terminal block
DC Output Connector
3 pin terminal block
User Port
Analog I/O: 15-pin female D-sub
Host Port
Digital I/O: 9-pin female RS232 and RS485
Parallel Bus
8-pin RJ46
Summary of Contents for HPH-20KA01KAT
Page 1: ...User Manual DC Power Supply Continuous 400 1000 VDC Model HPH 20KA01KAT Version Rev S 00...
Page 13: ...Delta Electronics Inc HPH 20KA01KAT 9...
Page 15: ...Delta Electronics Inc HPH 20KA01KAT 11...
Page 22: ...Delta Electronics Inc HPH 20KA01KAT 18...
Page 29: ...Delta Electronics Inc HPH 20KA01KAT 25 6 3 Main Menu Map Fig 6 1 Panel tree...