Following is information on monitoring the master/slave system depending on your monitoring
device:
1.
If you have a passive front panel attached to your master unit, you can view the
combined output of your master/slave system (power or current). The passive front
panel of each slave unit displays the individual unit’s output.
2.
If you have a host computer connected to a serial port on your master unit, you can
monitor the output (power, current or voltage) of your system and the output of each
individual unit.
3.
If you want more than two in parallel, you can’t set more than one master unit at the
same time.
5.8.
Clearing Faults in a Master/Slave System
If a slave unit experiences an a self-clearing fault, both the master and slave units display an
error code and the master unit shuts off output from all power supplies. When the fault condition
clears, the master and slave units reset. You may then turn on output.