Table 6.3 Protocol of RS232/485 definition (1)
Remote to PSU
Byte
0
1
2
3
4
5
6
7
8
9
10
IP
Command
Data1
Data2
Check Sum
Termination
Byte H-Byte
L-Byte
H-Byte L-Byte H-Byte L-Byte 0x00
Byte
0x00
0x0D
CV Mode
IP
0x11
0x00/01/02
0x00
0x00
Value
0x00
Value
0x00
0x0D
CC Mode
IP
0x12
0x00/01/02
0x00
0x00
Value
0x00
Value
0x00
0x0D
CP Mode
IP
0x13
0x00/01/02
0x00
0x00
Value
0x00
Value
0x00
0x0D
Master/Slave
IP
0x14
0x00/01
0x00
0x00
Value
0x00
Value
0x00
0x0D
A/Ri Offset
IP
0x15
0x00/01
0x00
0x00
00/01
Value
0x00
Value
0x00
0x0D
A/Vo Offset
IP
0x16
0x00/01
0x00
0x00
00/01
Value
0x00
Value
0x00
0x0D
A/Io Offset
IP
0x17
0x00/01
0x00
0x00
00/01
Value
0x00
Value
0x00
0x0D
Terminating
Resistor
IP
0x18
0x00/01
0x00
0x00
IP
Value
0x00
Value
0x00
0x0D
Set Point
IP
0x1A
0x00/01/02
Value
Value
0x00
Value
0x00
0x0D
Pause Time
IP
0x1B
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Energy Mode
IP
0x1D
0x00/01/02
Value
Value
0x00
Value
0x00
0x0D
Arc Function
IP
0x1E
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Parallel Number
IP
0x21
0x00/01/02
Value
Value
0x00
Value
0x00
0x0D
Max Power
IP
0x22
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Max Current
IP
0x23
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Max Voltage
IP
0x24
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Ramp Time
IP
0x25
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Target Life
IP
0x26
0x00/01/02
Value
Value
0x00
Value
0x00
0x0D
Delay time
IP
0x28
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Arc Voltage
IP
0x30
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Arc Density
IP
0x31
0x00/01/02
Value
Value
0x00
Value
0x00
0x0D
Arc Number
IP
0x32
0x00/01/02
Value
Value
0x00
Value
0x00
0x0D
Ignition
IP
0x33
0x00/01
Value
Value
0x00
Value
0x00
0x0D
Power On
IP
0x41
0x00/01/02
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Power Off
IP
0x42
0x00/01/02
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Default 1
IP
0x60
0x00
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Default 2
IP
0x61
0x00
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Default 3
IP
0x62
0x00
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Default 4
IP
0x63
0x00
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Reset
IP
0x45
0x00
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Version
IP
0x70
0x02
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Alarm Code/IP
IP
0x71
0x02
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
PSU State
IP
0x80
0x02
0x00
0x00
0x00
0x00
0x00
Value
0x00
0x0D
Note 6.1: For L-Byte of Command, 0x00 means writing command to MCU, 0x01 means reading
command from MCU, and 0x02 means reading feedback value.
Example:
CV Mode command code:
0x11 0x00 means writing command to MCU.
0x11 0x01 means reading command from MCU.
0x11 0x02 means reading voltage from feedback.
Summary of Contents for HPH-20KA01KAT
Page 1: ...User Manual DC Power Supply Continuous 400 1000 VDC Model HPH 20KA01KAT Version Rev S 00...
Page 13: ...Delta Electronics Inc HPH 20KA01KAT 9...
Page 15: ...Delta Electronics Inc HPH 20KA01KAT 11...
Page 22: ...Delta Electronics Inc HPH 20KA01KAT 18...
Page 29: ...Delta Electronics Inc HPH 20KA01KAT 25 6 3 Main Menu Map Fig 6 1 Panel tree...