7.2.
D-sub Operating Steps
Example : CP mode 20 kW output
Operating steps:
1.
Set the front panel => Interface Setup => Communnication Setup => D-sub.
2.
Command Level: Set +10 V input to pin 5 for 20 kW Command.
3.
Power On: Connect pin 4 to pin 9
4.
Power Off: Remove pin4 from pin 9.
7.3.
RS-232 Operating Steps
1.
Set the front panel => Interface Setup => Communnication Setup => RS-232.
2.
Follow the protocol defined in chapter 6.4 to operating.
7.4.
RS-485 Operating Steps
1.
Set the front panel => Interface Setup => Communnication Setup => RS-485.
2.
Follow the protocol defined in chapter 6.4 to operating.
7.5.
Parallel Operating Steps
Parallel operating example 1: Two sample parallel
Operating steps:
1.
Connecting set up follow chapter 5
2.
Panel System Configuration
Parallel Number
2
3.
Parallel port 5~8 set IP position, two sample must set up different IP
Example: sample 1 set 0000, sample 2 set 0001
4.
Than can follow chapter 7.1 turn on output
Parallel operating example 2: Three sample parallel
Operating steps:
1.
Connecting set up follow chapter 5
2.
Panel System Configuration
Parallel Number
3
3.
Parallel port 5~8 set IP position, two sample must set up different IP
Example: sample 1 set 0000, sample 2 set 0001,sample 3 set 0010
4.
Than can follow chapter 7.1 turn on output
Summary of Contents for HPH-20KA01KAT
Page 1: ...User Manual DC Power Supply Continuous 400 1000 VDC Model HPH 20KA01KAT Version Rev S 00...
Page 13: ...Delta Electronics Inc HPH 20KA01KAT 9...
Page 15: ...Delta Electronics Inc HPH 20KA01KAT 11...
Page 22: ...Delta Electronics Inc HPH 20KA01KAT 18...
Page 29: ...Delta Electronics Inc HPH 20KA01KAT 25 6 3 Main Menu Map Fig 6 1 Panel tree...