Delta Din-rail Power Meter DPM-D520I User
Manual
5-16
_5
AD
40174
exceeding this value
triggers alarm)
AE
40175
Pickup time delay
(alarm–trigger delay) 0 – 99
word
s
2
R/W
AF
40176 Dropout setpoint
(frequency value
below this value
clears alarm)
0.0000 – 99.9999
float
Hz
4
R/W
B0
40177
B1
40178
Dropout time delay
(alarm–clear delay)
0 – 99
word
s
2
R/W
Alarm – Under Frequency
B2
40179 Alarm enable
0: Disable
1: Enable
word
2
R/W
B3
40180
Pickup setpoint
(frequency value
below this value
triggers alarm)
0.0000 – 99.9999
float
Hz
4
R/W
B4
40181
B5
40182
Pickup time delay
(alarm–trigger delay) 0 – 99
word
s
2
R/W
B6
40183
Dropout setpoint
(frequency value
exceeding this value,
alarm cleared)
0.0000 – 99.9999
float
Hz
4
R/W
B7
40184
B8
40185
Dropout time delay
(alarm–clear delay)
0 – 99
word
s
2
R/W
Alarm – Over THD Voltage