SWT4 User Manual v3.1
Installation
17
Conduit:
This pictures shows an example of
the use of flexible cable conduit (trunking) to
protect the tensiometer cables.
3.1.6 Ideal conditions for installation
For the installation of Tensiometers, the ideal conditions are:
Frost-free soil.
Wet coarse clay or loess (wind deposited soil).
Low gravel content. The more gravel in a soil the more often the
drilling has to be repeated to reach the required depth.
3.1.7 Documentation
For every measuring spot you should:
Measure out the position where the pressure sensor will be
placed. (A must for installations below the ground surface).
Take documentary photos before, during and after installation.
Save a soil sample.
Write down installation depth and angle with each sensor
identification (serial number).
Mark all connecting cables with the corresponding sensor
identification, serial number or logger channel on each end.
Clip-on numbered rings are available as
an accessory.
Contact Delta-T for more information.