SWT4 User Manual v3.1
Protecting the measuring site
35
5.3.2 Emptying SWT4 or SWT4R
Also read chapter 4.1.
SWT4R Tensiometers:
1) Remove the connecting rubber tube from the refilling tube. In a
downwards installation the refilling tube is the marked tube, in an
upwards installation the refilling tube is the unmarked tube.
2) Connect the empty syringe to the refilling tube and completely suck
out the Tensiometer water.
3) Re-connect rubber tubes and filling tube.
SWT4 Tensiometer,
if installed within the depth of frost
penetration, must be removed and stored in a frost-free place.
5.4 Lightning protection and grounding
In-the-field measuring equipment is always susceptible to electrical
surge. Our equipment is protected against over-voltage and wrong
polarity as far as this is technically achievable.
There never can be total lightning protection. Lighting strikes are
unpredictable and vary significantly with region, voltage and
destructiveness. Proper lightning protection has to be considered
whenever a system with several sensors and loggers is installed.
Passive lightning protection measures would comprise one or more
grounding rods, preferably with ground water contact, but without (!) an
electrical connection to the measuring system.
With an active lightning protection each sensor and the logger are
equipped with an individual grounded surge protection module.
Unfortunately, these are very expensive.
Please contact Delta-T or your distributor for assistance about
integrating SWT4 or SWT4R into your measurement system.