background image

 

Specifications      

DC Output – see Operating Instructions 

QuiQ Model: 912- 

24xx 

36xx 

48xx 

72xx 

Voltage-nom (V) 

24 

36 

48 

72 

Voltage-max (V) 

33.6 

50.4 

67.2 

100 

Current-max (A) 

25 

21 

18 

12 

Battery Type 

Specific to selected algorithm 

Reverse Polarity  

Electronic protection – auto-reset 

Short Circuit 

Electronic current limit  

AC Input 

All models 

 

Voltage-max (Vrms) 

85 – 265  

Frequency (Hz) 

45 - 65 

Current-max (Arms) 

12A @ 104VAC (reduced 20%<104V) 

Current – nominal (Arms) 

10A @ 120VAC / 5A @ 230VAC 

AC Power Factor 

>0.98 at nominal input current 

Operation 

 

Charger Model: 912- 

xx0x (10 LED) 

xx1x (1 LED) 

AC ON  

Solid YELLOW  

LED Active 

AC LOW 

Flash YELLOW  

Flash YELLOW 

Thermal Cutback 

Flash Bargraph 

Flash YELLOW 

<80% Charge Indicator 

Short Flash GREEN 

>80% Charge Indicator 

Solid YELLOW 

Long Flash GREEN 

100% Charge Indicator 

Solid GREEN 

Solid GREEN 

Fault Indicator 

Flash RED 

Flash RED 

DC Ammeter 

LED Bargraph 

Bat Temp Compensation 

Automatic 

Optional 

Maintenance Mode 

Auto-restart if V<2.1Vpc or 30 days elapse 

 
 
 
 
 
 
 
 
 
 
 
 

 

Mechanical 

Regulatory 

 
 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

All models 

 

Dimensions 

28.0 x 24.5 x 11.0 cm (11 x 9.7 x 4.3”) 

Weight 

<5 kg (<11 lbs) w/ standard output cord 

Environmental  

Enclosure: IP46 

Operating 
Temperature 

-30°C to +50°C (-22°F to 122°F), derated 

above 30°C, below 0°C 

Storage Temperature 

-40°C to +70°C (-40°F to 158°F) 

AC input connector 

IEC320/C14 (require  1.8m localized cord) 

DC output connector 

OEM specific w/ 12AWG wire 

Safety 

 

EN 60335-1/2-29 

Safety of Appliances/ Battery Chargers  

UL2202 

EV Charging System Equipment 

UL1564 2nd Edition 

Industrial Battery Charger 

CSA-C22.2 No. 107.2 

Battery Chargers- Industrial 

Emissions 

 

FCC Part 15/ICES 003 

Unintentional Radiators Class A 

EN 55011 

Radio disturbance characteristics (Class A) 

EN 61000-3-2  

Limits for harmonic current emissions  

EN 61000-3-3  

Limits of voltage fluctuations and flicker  

Immunity 

 

EN 61000-4-2  

Electrostatic discharge immunity  

EN 61000-4-3  

Radiated, radio-frequency, EMF immunity  

EN 61000-4-4  

Electrical fast transient/burst immunity  

EN 61000-4-5 

Surge immunity  

EN 61000-4-6  

Conducted Immunity 

EN 61000-4-11 

Voltage variations immunity  

Installation Instructions     

WARNING: The output of chargers with greater than 48V may 
pose an energy and/or shock hazard under normal use. These 

units must be installed in the host equipment in such a 
manner that the output cable and battery connections are 

only accessible with the use of a tool by qualified personnel.

 

1) Determine Mounting Location: 

While its sealed nature allows the charger to be mounted virtually 
anywhere, the choice of mounting location and orientation is 
extremely important. For optimum performance and shortest 
charge times, mount the charger in an area with adequate 
ventilation. The charger should also be mounted in an area that 
will be relatively free of oil, dirt, mud, or dust since accumulations 
within the fins of the charger will reduce their heat-dissipating 
qualities.  Optimal cooling also occurs when the charger is 
mounted on a horizontal surface with the fins vertical.  More 
airflow from below the charger will help cool the fins, so mounting 
above open areas or areas with cut-outs for airflow is desirable.  
Contact Delta-Q for information on other mounting orientations.  
As the charger may get hot in operation, the charger must be 
installed such that risk of contact by people is reduced. The 
charger’s AC plug must be located at least 18” above the floor/ 
ground surface and the status display must be visible to the user. 

2) Mounting Procedure:  

Mount the charger by the mounting plate using appropriate 
fasteners (i.e. 1/4" or M6 with locking hardware). For UL2202 
compliance, a 12AWG green bonding wire with ring terminals 
must be attached from the bonding stud located on the front of the 
charger (identified by     ) to the vehicle frame. The vehicle 
connection must be made using corrosion resistant hardware 
(e.g., a #10 stainless steel machine screw with at least two 
threads of engagement and, if required, a paint piercing washer). 

3) DC Battery Connection Procedure:  

a) The green wire outputs battery voltage when the charger is not 

plugged into AC to provide an interlock function – see Fig. 1. 

If 

used, a user-supplied 1A fast-blow external fuse must be 

installed inline to prevent damage. Shorting or drawing 

more than 1A may damage charger and void the warranty.

 

b) Securely fasten the black ring terminal from the charger to the 

negative terminal ("-", "NEG", NEGATIVE") of the battery pack.   

c) Check that the correct charge algorithm is being used – refer to 

section 4). Securely fasten the red ring terminal to the positive 
terminal ("+", "POS", "POSITIVE") of the battery pack.   

 

4) Check / Change Charging Algorithm: 

The charger comes pre-loaded with algorithms for batteries as detailed in Table 
1. If your specific battery model is not listed, please contact Delta-Q.  
Each time AC power is applied with the battery pack NOT connected, the 
charger enters an algorithm select/display mode for approximately 11 seconds. 
During this time, the current Algorithm # is indicated on the ‘80%’ LED (Models 
912-xx0x) or on the single LED (Models 912-xx1x).  A single digit Algorithm # is 
indicated by the number of blinks separated by a pause. A two digit Algorithm # 
is indicated by the number of blinks for the first digit followed by a short pause, 
then the number of blinks for the second digit followed by a longer pause.  
To check / change the charging algorithm: 
a) Disconnect the charger positive 

connector from battery pack. Apply AC 
power and after the LED test, the 
Algorithm # will display for 11 seconds. 

b) To change algorithm, touch positive 

connector during the 11 second display 
period to the battery pack’s positive 
terminal for 3 seconds and then remove 
– the Algorithm # will advance after 3 
seconds. Repeat until desired Algorithm 
# is displayed. A 30 second timeout is 
extended for every increment. 
Incrementing beyond the last Algorithm 
moves back to the first Algorithm.  
After desired Algorithm # is displayed, 
 touch the charger connector to the battery positive until the output relay is 
heard to click (~10 seconds) – algorithm is now in permanent memory. 

c) Remove AC power from the charger and reconnect the charger positive 

connector to the battery pack. It is highly recommended to check a newly 
changed algorithm by repeating step 4) above. 

 

Product warranty is two years - please contact dealer of original equipment for warranty 

service.  

 

Note: This is a Class A product. In a domestic environment this product may cause radio 

interference, in which case the user may be required to take adequate measures. 

 

July 2006 © Delta-Q Technologies Corp.  All rights reserved.  PN: 710-xxxx Rev 1 V1.16 

Alg 

Battery Type 

43 

Discover AGM  

27 

Crown CR-325 

21 

Exide Flooded 

12 

Exide/Sonnenschein Gel  

J305 DV/DT CP 

DEKA 8G31 Gel 

Trojan  30/31XHS 

US Battery USB2200 

T105 DV/DT CP  

Trojan T105 

Table 1. 

 

 

B+  

Interlock 

Charger  

Internal 

Output 

Figure 1 

F1 

NC 

NO 

F2 

GRN 

B- 

BLK/WHT 

RED 

1A 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for QuiQ 912-24 series

Page 1: ...time will vary by how large and how depleted the battery pack is the input voltage the higher the better and ambient temperatures the lower the better If the input AC voltage is low below 104VAC then...

Page 2: ...e and the status display must be visible to the user 2 Mounting Procedure Mount the charger by the mounting plate using appropriate fasteners i e 1 4 or M6 with locking hardware For UL2202 compliance...

Page 3: ...rrent output reduced Provide better airflow to the charger Try to move the charger to a cooler location Confirm that dirt or mud is not blocking the cooling fins of the charger Clean the charger Rinse...

Page 4: ...ed time This could occur if the battery is of larger capacity than the algorithm is intended for In unusual cases it could mean charger output is reduced due to high ambient temperature It can also oc...

Page 5: ...has started charging normally be sure to make a note of it Try to clear the fault by unplugging AC power waiting 30 seconds and reconnecting the AC Check all battery connections Look for a high resis...

Page 6: ...for this problem is incorrect charge algorithm setting and or high ambient temperatures Confirm that the battery pack is not too small usually 50Ah Confirm that the nominal battery voltage matches the...

Page 7: ...ge algorithm to correct setting for batteries No Connect charger to batteries and plug charger into AC Yes Does the Red LED indicate a fault Is the interlock functioning if used Note that the interloc...

Page 8: ...ee above you are ready to connect your QuiQ charger to the computer with the QuiQ USB Interface Module Step 1 Disconnect AC power from QuiQ charger Step 2 Disconnect QuiQ charger from batteries and co...

Page 9: ...erify communications with the charger See screen image below The No Charger Detected message indicates that the QuiQ Programmer is unable to communicate with your charger This could be due to one of t...

Page 10: ...charger It will take around 1 2 seconds to load or To upgrade the software of the charger Select the version of software you want to add from the Computer s list of Charger Software Versions and click...

Reviews: