 QuiQ Charger Troubleshooting Flow Chart

Does the

Charger Turn

On?

Disconnect charger from batteries

and connect to AC Power

Yes

No

Ensure 90-
260VAC at

Charger Input

Does the

Charger Turn

On?

Yes

No

Check for correct algorithm

number (refer to manual for

procedure)

Charger Input Failure -

Return Unit

Does the

algorithm

 match the

batteries?

Change algorithm to correct

setting for batteries.

No

Connect charger to batteries

and plug charger into AC.

Yes

Does the

 Red LED indicate

 a fault?

Is the

 interlock

functioning? (if

used)

Note that the interlock is not

functioning and return

charger

Charger is OK

Yes

Yes

No

Refer to troubleshooting guide to try and resolve

problem.  If problem persists make note of the

problem and return charger

No

Is there

excessive boiling or

other odd behaviour

while charging?

No

Yes

 

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Summary of Contents for QuiQ 912-24 series

Page 1: ...time will vary by how large and how depleted the battery pack is the input voltage the higher the better and ambient temperatures the lower the better If the input AC voltage is low below 104VAC then...

Page 2: ...e and the status display must be visible to the user 2 Mounting Procedure Mount the charger by the mounting plate using appropriate fasteners i e 1 4 or M6 with locking hardware For UL2202 compliance...

Page 3: ...rrent output reduced Provide better airflow to the charger Try to move the charger to a cooler location Confirm that dirt or mud is not blocking the cooling fins of the charger Clean the charger Rinse...

Page 4: ...ed time This could occur if the battery is of larger capacity than the algorithm is intended for In unusual cases it could mean charger output is reduced due to high ambient temperature It can also oc...

Page 5: ...has started charging normally be sure to make a note of it Try to clear the fault by unplugging AC power waiting 30 seconds and reconnecting the AC Check all battery connections Look for a high resis...

Page 6: ...for this problem is incorrect charge algorithm setting and or high ambient temperatures Confirm that the battery pack is not too small usually 50Ah Confirm that the nominal battery voltage matches the...

Page 7: ...ge algorithm to correct setting for batteries No Connect charger to batteries and plug charger into AC Yes Does the Red LED indicate a fault Is the interlock functioning if used Note that the interloc...

Page 8: ...ee above you are ready to connect your QuiQ charger to the computer with the QuiQ USB Interface Module Step 1 Disconnect AC power from QuiQ charger Step 2 Disconnect QuiQ charger from batteries and co...

Page 9: ...erify communications with the charger See screen image below The No Charger Detected message indicates that the QuiQ Programmer is unable to communicate with your charger This could be due to one of t...

Page 10: ...charger It will take around 1 2 seconds to load or To upgrade the software of the charger Select the version of software you want to add from the Computer s list of Charger Software Versions and click...

Reviews: