VIVOTEK
User's Manual - 345
© 2022 VIVOTEK INC. All Right Reserved
206
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
enhancement
tour_index
-1, 0~19
1/4
Index of the enabled tour group,
from 0 to 19.
Set -1 to disable all the tour
groups.
tour_i<0~19>_name
string[40]
1/4
Name of the tour.
tour_i<0~19>_type
<boolean>
1/4
0 = Recorded tour
1 = Preset tour
tour_i<0~19>_speed
-5 ~ 5
1/4
Preset tour: pan and tilt speed
when moving between presets.
Recorded tour: unnecessary.
tour_i<0~19>_direction forward,backward,ra
ndom
1/4
User can choose which direction
the preset tour goes.
"forward"
: preset tour goes in
forward order.
"backward"
: preset tour goes in
backward order.
"random"
: the presets of the tour
will be recalled randomly.
* Only available when
"capability_presettourdirection"
is 1.
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0307a.
tour_i<0~19>_checklist string[512]
1/4
The indexes of preset positions,
separated by “,”
tour_i<0~19>_dwelltim
e
string[512]
1/4
Preset tour: time to wait before
moving to the next preset
position, separated by “,”
Recorded tour: number of
seconds to wait
before continuing a loop tour.
tour_i<0~19>_enabletra
ck
<boolean>
1/4
Whether the "preset tour" enters
the tracking mode during the
dwell time
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0317a.
P
LEASE REFER TO
PTZ
C
ONTROL
API
© 2022 VIVOTEK INC. All Right Reserved
207
7.42
UART Control
Group:
uart
(capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ptzdrivers_i<0~19,
127>_name
string[40]
1/4
Name of the PTZ driver.
ptzdrivers_i<0~19,
127>_location
string[128]
1/4
Full path of the PTZ driver.
enablehttptunnel
<boolean>
1/4
Enable HTTP tunnel channel to control
UART.
Group:
uart_i<0~(n-1)>
n is uart port count
(capability_nuart > 0 and capability_fisheye = 0)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
baudrate
300,600,1200,2400,
4800,9600,19200,38
400,57600,115200
4/4
Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit
none,
odd,
even
4/4
For error checking.
stopbit
1,2
4/4
"1"
: One stop bit is transmitted to
indicate the end of a byte.
"2"
: Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the uart_i<0~(n-
1)>_stopbit should be set as 2 and the
uart_i<0~(n-1)>_databit set as 5 as
well.
uartmode
rs485,
rs232
4/4
RS485 or RS232.
customdrvcmd_i<0~
9>
string[128]
1/4
PTZ command for custom camera.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_n
ame
string[40]
1/4
Additional PTZ command name.
* only available when
capability_camctrl_c0_rs485=2
speedlink_i<0~4>_c
md
string[40]
1/4
Additional PTZ command list.
* only available when
capability_camctrl_c0_rs485=2
ptzdriver
0~19,
127 (custom),
1/4
The PTZ driver is used by this COM
port.