VIVOTEK
344 - User's Manual
© 2022 VIVOTEK INC. All Right Reserved
206
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
enhancement
tour_index
-1, 0~19
1/4
Index of the enabled tour group,
from 0 to 19.
Set -1 to disable all the tour
groups.
tour_i<0~19>_name
string[40]
1/4
Name of the tour.
tour_i<0~19>_type
<boolean>
1/4
0 = Recorded tour
1 = Preset tour
tour_i<0~19>_speed
-5 ~ 5
1/4
Preset tour: pan and tilt speed
when moving between presets.
Recorded tour: unnecessary.
tour_i<0~19>_direction forward,backward,ra
ndom
1/4
User can choose which direction
the preset tour goes.
"forward"
: preset tour goes in
forward order.
"backward"
: preset tour goes in
backward order.
"random"
: the presets of the tour
will be recalled randomly.
* Only available when
"capability_presettourdirection"
is 1.
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0307a.
tour_i<0~19>_checklist string[512]
1/4
The indexes of preset positions,
separated by “,”
tour_i<0~19>_dwelltim
e
string[512]
1/4
Preset tour: time to wait before
moving to the next preset
position, separated by “,”
Recorded tour: number of
seconds to wait
before continuing a loop tour.
tour_i<0~19>_enabletra
ck
<boolean>
1/4
Whether the "preset tour" enters
the tracking mode during the
dwell time
* We support this parameter
when the version number
(httpversion) is equal or greater
than 0317a.
P
LEASE REFER TO
PTZ
C
ONTROL
API