35
EN
1/ INSTALLATION
Connection instructions for IN1 - COM - IN2 terminals
Use the wires supplied.
Push the wire fully into the terminal.
Connection
- Connect the motor control wires to terminals 3 and 4
(motor lowering control wire to terminal 3, raising control wire to terminal 4).
- Connect the switch to the IN1 - COM - IN2 terminals.
- Connect the 230 V power supply to terminals 1 and 2.
- Switch the installation power back on to continue with the association operation.
Do not strip the wires when they are
connected to the product as you could
damage the internal connector.
2
7mm
0,5 mm
KY31A02
1
2
3
4
230V
230 V~
IN1
COM
IN2
1
2
3
4
TYXIA
1 2 3 4
IN1
COM
IN2
IN1
COM
IN2
IN1
COM
1
2
3
1
2
1
2
Hold switch
Double push-button
Push button
Removal recommendations
Turn the wire while pulling on it.
1
2
1
2
3
4