34
1.3 RECEIVER FOR TYXIA 5630 ROLLER SHUTTER
Recommendations
• IMPORTANT: the control wires are not insulated
from the mains power supply. All connected
equipment must be marked CE and meet the
requirements of the low voltage devices as well as
assembly recommendations.
Local control wires can be extended up to 10 m
(separate from the 230 V).
• The roller shutter high and low stops must be set
before the receiver is installed.
You can install the receiver for roller shutter in a fl ush-
mounted box behind a switch or control push-button or in
a sealed box inside the roller shutter, a safe distance from
metal parts.
Connection instructions for terminals 1 2 3 4
- Strip the wires while respecting the strip length
specifi ed on the product.
- Push the wire fully into the terminal.
• Solid wires
• Stranded wires
0,75 - 1,5 mm
Ø
2
1/ INSTALLATION
Use an electrically
isolated tool to
perform the actions
on the receiver
confi guration
button.
Switch off the installation
power supply
2
1
IPx4
230V~
OFF
Removal recommendations
- Switch off the power supply.
- Use the tool supplied or a 2.5 mm screwdriver to press the
button of the front terminal before removing the wire.
Using the tool
supplied or a 2.5 mm
screwdriver, press the
terminal button then
insert the wire.
10A circuit breaker
required.
10 A
2
1
Summary of Contents for TYXIA 641