To restore the factory settings while deleting all associations and all the current defects.
If an alarm control unit is associated with the transmitter, set it to maintenance mode (see system guide).
14. Initialisation (restoring factory settings)
with an alarm control unit or in autonomous mode.
Open the transmitter unit
Only in
autonomous mode
RESET OK
>30s
BIP... BIP
>30s
BIP
BIIIIP
>5s
>15s
T2
T2
Press the T2 button for 30
seconds
The transmitter is in its initial state, all the associations are deleted
as well as all the current defects.
After 5 seconds, the transmitter beeps once,
keep holding the button down.
After 15 seconds, the transmitter beeps twice,
keep holding the button down.
After 30 seconds, the transmitter emits a long beep.
13. Access code initialisation
with an alarm control unit without keypad or in autonomous mode
Open the transmitter unit
>15s
BIP... BIP
BIP
>5s
>15s
Only in
autonomous mode
T2
T2
Press the T2 button for 15 seconds
After 5 seconds, the transmitter beeps once,
keep holding the button down.
After 15 seconds, the transmitter beeps twice,
release.
The access code is 1 2 3 4 5 6 again.
To restore the factory setting 1 2 3 4 5 6.
If an alarm control unit is associated with the transmitter, set it to MAINTENANCE mode (see system guide).
15. Summary of configuration commands
Association/Deletion
Configuration menu
Function
Heating
#400
1 = Enabled, 0 = Disabled
Roller shutters
#410
#411
1 = Enabled, 0 = Disabled
Lighting
#420
#421
1 = Enabled, 0 = Disabled
Gate
#430
1 = Enabled, 0 = Disabled
Scenarios
Configuration menu
Function
#601
#602
#603
#604
1 = Enabled, 0 = Disabled
Remote monitoring
Configuration menu
Function
Configuration of CESA loop numbers
#70
1 = Enabled, 0 = Disabled
Listing of CESA loop numbers
#71
1 = Enabled, 0 = Disabled
Alarm control unit monitoring
#811
1 = Enabled, 0 = Disabled
Transmission to remote monitoring operator
#821
1 = Enabled, 0 = Disabled
Cyclic test
#822
1= Daily, 0= Regular
Call to voice numbers
#824
1= Calls, 0= No call
Fast pick-up method
#826
1= Authorised, 0= Unauthorised
Software version
#83
Remote monitoring code inversion
#84
1= Inverted, 0= Normal
GSM level
#86
Test call cycle 15s after hanging up
#90
Transmitter ID input (5 digits)
#91
Main number for the remote monitoring
operator input
#92
Emergency telephone number for remote
monitoring input
#93
Cyclic test frequency input
#94
Remote monitoring protocol selection
# 95 00
TLS_CESA_P0
# 95 01
TLS_CESA_P1
# 95 02
TLS_CESA_P2
# 95 10
TLS_COID_P10
# 95 11
TLS_COID_P11
# 95 12
TLS_COID_P12
# 95 13
TLS_COID_P13
Verification of settings
# 96
from #91 to #95