TMC 188/40 Motion Control Module
V Memory
Delta Computer Systems, Inc. 360/254-8688
19
VREAD - Axis Position and Status Parameters
WY Register 5 is the V Memory address where the following parameters are stored:
V Memory
Location
Parameter Name
Axis 1-4 Position and Status Data
Descriptions
1
Axis 1 Command Position
Command position (within set limits)
2
Axis 1 Target Position
Calculated instantaneous position (scaled)
3
Axis 1 Actual Position
Measured axis position (scaled)
4
Axis 1 Transducer Counts
Transducer location in raw counts
5
Axis 1 Status
Error and status bits
6
Axis 1 Drive
Drive output in raw D/A counts
7
Axis 1 Target Speed
Calculated axis speed (scaled)
8
Axis 2 Command Position
Command position (within set limits)
9
Axis 2 Target Position
Calculated instantaneous position (scaled)
10
Axis 2 Actual Position
Measured axis position (scaled)
11
Axis 2 Transducer Counts
Transducer location in raw counts
12
Axis 2 Status
Error and status bits
13
Axis 2 Drive
Drive output in raw D/A counts
14
Axis 2 Target Speed
Calculated axis speed (scaled)
15
Axis 3 Command Position
Command position (within set limits)
16
Axis 3 Target Position
Calculated instantaneous position (scaled)
17
Axis 3 Actual Position
Measured axis position (scaled)
18
Axis 3 Transducer Counts
Transducer location in raw counts
19
Axis 3 Status
Error and status bits
20
Axis 3 Drive
Drive output in raw D/A counts
21
Axis 3 Target Speed
Calculated axis speed (scaled)
22
Axis 4 Command Position
Command position (within set limits)
23
Axis 4 Target Position
Calculated instantaneous position (scaled)
24
Axis 4 Actual Position
Measured axis position (scaled)
25
Axis 4 Transducer Counts
Transducer location in raw counts
26
Axis 4 Status
Error and status bits
27
Axis 4 Drive
Drive output in raw D/A counts
28
Axis 4 Target Speed
Calculated axis speed (scaled)