V Memory
TMC 188/40 Motion Control Module
Delta Computer Systems, Inc. 360/254-8688
18
VINIT - Axis Initialization Parameters
WY Registers 1-4 are the V Memory addresses where the following parameters are stored:
V Memory
Location
Parameter Name
Default Value
Initialization Parameters
Descriptions
1
NEW NULL
2048
Zero offset for drive
2
ESTOP Mask
0FFFF
Disable emergency stop on error
condition
3
HALT Mask
00000
Disable halt on error condition
4
Reserved
0FFFF
Not used at this time
5
FEED FORWARD ADVANCE
0
Feed forward advance (in
milliseconds)
6
NULL UPDATE
500
Time interval in at which null drive is
calculated (in milliseconds)
7
Reserved
0FFFF
Not used at this time
8
DITHER
0
Static friction drive
9
HYSTERESIS
0
Deadband compensation
10
STATIC GAIN
50
Proportional gain at rest
11
EXTEND GAIN
50
Proportional gain when extending
12
RETRACT GAIN
50
Proportional gain when retracting
13
INTEGRAL GAIN
50
Integral gain when in motion
14
DIFFERENTIAL GAIN
0
Differential gain when in motion
15
EXTEND FEED FORWARD
100
Feed-forward drive when extending
16
RETRACT FEED FORWARD
100
Feed forward drive when retracting
17
SCALE
32768
Converts TRANSDUCER COUNTS
to position units
18
POSITION OFFSET
0
Offset between position zero and
transducer count zero
19
DIRECTION
0
Direction relative to TRANSDUCER
COUNTS (0=+, -1= -)
20
MAX ERROR
250
Position error limit
21
AT COMMAND POSITION
50
Maximum position error size for a
„true‟ status bit indication
22
NEAR COMMAND POSITION
0
Maximum position error size for a
„true‟ status bit indication
23
EXTEND LIMIT
Position at
power-up
Maximum position in position units
24
RETRACT LIMIT
Position at
power-up
Minimum position in position units