YDT-35 Operating and Servicing Manual
HL066(EN) ISSUE 1, 05/2015
41
RFM .EJBR-######
Adjust to MAX Pressure.
Press START when ready . . .
180” Bar: 1000
Figure 4.25 RFM Test Start Screen
When ready to start the test, press the START
key. Refer to Figure 4.26.
The 180 second timer starts counting down; the elapsed test time is indicated at the bottom of the
screen.
RFM .EJBR-######
Please consult the
Operating Manual . . .
START=Test, STOP=Next
95”
Figure 4.26 RFM Test in Progress
The injector has maximum pressure applied, with no injection pulse.
Observe the flow measurement on the backleak flow indicator.
The test assessment is purely visual. There are no pass/fail indications on-screen that the injector is
acceptable or not. The operator must determine by
observation and comparison with a known ‘good’
injector, whether the backleakage (return) flow is acceptable. In an ideal injector, the flow in this test
would be zero.