YDT-35 Operating and Servicing Manual
HL066(EN) ISSUE 1, 05/2015
13
1.2 Specification & Site Requirements
Dimensions
Height 750mm
Width 680mm
Depth 440mm
Weight
Dry Weight 30 kg
Electrical supply
Single phase, 100
– 250Vac, 2 Amp, 50 / 60 Hz
Air supply
Clean, dry air
Minimum pressure 5 bar (72.5 psi)
Maximum 10 bar (145 psi)
Minimum flow rate 100L/min.
Max hydraulic operating pressure
1000 Bar
Measurement
Back leakage measurement (optional)
0
34 ml/min Back leakage
Universal injector clamping
Clamping diameter
– 17mm
30.5mm
Filtration
Replaceable 2 micron filter (test fuel tank)
Screen filter (backleak)
Fluid tank volume
3 Litres
Compatible test fluid
ISO 4113 (See Health & Safety Datasheet prior to use)
1.3 Definition of Terms and Abbreviations
CAP
Capacitance (Piezo Injector Only)
CR
Common Rail
IND
Inductance (Coil Injector Only)
IPM
Injections per Minute
ISF
Injector Spray Function Test
uS
Injector Pulse Width (Micro Seconds)
NOP
Nozzle opening pressure (bar)
OHM
Resistance (Coil Injector Only)
PCB Printed Circuit Board
RFM
Return (Backleak) Flow Measurement Test
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.