background image

 

1.

 

INTRODUCTION ........................................................................................... 3

 

2.

 

MAIN FEATURES ......................................................................................... 3

 

3.

 

TECHNICAL SPECIFICATIONS ................................................................... 3

 

4.

 

CONNECTION AND SET UP OF THE CONTROL UNIT.............................. 4

 

4.1

 

GENERAL DIAGRAM OF SETTINGS AND CONNECTIONS .................................. 5

 

4.2

 

SIMPLIFIED LEARNING PROCEDURE (also see pages 8-10) .............................. 6

 

4.3

 

PROFESSIONAL LEARNING PROCEDURE (see also pages 8-10)...................... 7

 

5.

 

CONTROL UNIT OPERATING L OGIC (ANALYTIC EXAM) ........................ 8

 

5.1

 

PROGRAMMING AND CANCELLATION  OF THE REMOTE CONTROLS ............. 8

 

5.2

 

OPERATION OF THE SAFETY DEVICES ............................................................... 8

 

5.3

 

MOTOR SPEED -  TRIMMER “FOR” ....................................................................... 9

 

5.4

 

DELAY BETWEEN MOTORS  -  TRIMMER “DEL” .................................................. 9

 

5.5

 

“OPENING AND CLOSING” OPERATING MODE .................................................. 9

 

5.6

 

“PEDESTRIAN OPENING” FUNCTION ................................................................. 11

 

5.7

 

“OBSTACLE SENSITIVITY” DETECTION - TRIMMER “OBS”............................. 11

 

5.8

 

FLASHING LIGHT .................................................................................................. 11

 

5.9

 

GATE OPEN WARNI NG LIGHT............................................................................. 11

 

5.10

 

SLOW-DOWN ......................................................................................................... 11

 

5.11

 

ELECTRIC LOCK ................................................................................................... 11

 

5.12

 

COURTESY LIGHT................................................................................................. 12

 

5.13

 

BUFFER BATTERY – SOLAR  PANEL MANAG EMENT ....................................... 12

 

5.14

 

LOGICAL STOP (STP INPUT)................................................................................ 12

 

5.15

 

CONTROL UNIT MEMORY FAUL T........................................................................ 12

 

6.

 

SIGNALLING LED....................................................................................... 12

 

7.

 

PROGRAMMING THROUGH GTSYSTEM ................................................. 13

 

8.

 

TROUBLESHOOTING ................................................................................ 14

 

SAFETY WARNINGS FOR INSTALLATION  AND USE ................................................... 15

 

 
 
 
 
 

Summary of Contents for SIRIO 3

Page 1: ...his manual that is an integral part of this Kit BAME S r l declines any responsibility in the event current standards in the country of installation are not complied with The symbol CE conforms with E...

Page 2: ...5 2 OPERATION OF THE SAFETY DEVICES 8 5 3 MOTOR SPEED TRIMMER FOR 9 5 4 DELAY BETWEEN MOTORS TRIMMER DEL 9 5 5 OPENING AND CLOSING OPERATING MODE 9 5 6 PEDESTRIAN OPENING FUNCTION 11 5 7 OBSTACLE SEN...

Page 3: ...or start 1 to 60 stand by time adjustment via trimmer 0 1 to 3 0 obstacle detection triggering time adjustment via trimmer Initial settings using dip switches Signalling LEDs 8 Expansion for electric...

Page 4: ...correct connection and operation of all the accessories connected to the terminal board NOTES INITIAL FACTORY SETTINGS If there is no programming the control unit will operate as follows Step step mo...

Page 5: ...ET RF MODULE FUSE 1 A Mains Transformer 230 12VAC for motors 12VDC Transformer 230 20VAC for motors 24VDC MOTOR 12 VDC max 50W 24VDC max 60W PHO and STP inputs must be bridged if not used Flashing lig...

Page 6: ...re from RESET the manoeuvre time changes The two leaves close until mechanical stop or electrical limit switches Yellow LED switches off The first leaf closes RESET press and hold the programming butt...

Page 7: ...rol button 1 The gate closes Will pedestrian function be used Press together P1 SET and P2 RAD Press the button of the remote control that will be used for the pedestrian function different from 1 Con...

Page 8: ...RPA learning pushbutton also see the instructions of the TX used Carry out this operation 5 6 metres from the receiver the LED signals the activation Transmit by pressing one of the channel pushbutto...

Page 9: ...f the motor if 50 of the maximum speed ATTENZION Changing the setting of trimmer FOR requires repeating the learning procedure since the travel times and the slow down start times change EXAMPLE Speed...

Page 10: ...er case the control unit disables the automatic closing and another command must be given to re start the manoeuvre If the automation is completely open once the pause time has elapsed the closing man...

Page 11: ...n of the motion for 2 seconds unless it is in the last five seconds of the manoeuvre where does a STOP 5 8 FLASHING LIGHT The control unit has two output terminals LAMP to command a low voltage flashi...

Page 12: ...l unit is turned on should there be a fault in the EEPROM memory the red LED flashes and all manoeuvres are blocked The Reset function must be executed press and hold the programming button P1 SET for...

Page 13: ...he GTSYSTEM is an autonomous multi functional terminal that can be used on various BAME products both for testing and function modification In the case of SIRIO3 12 24 control unit it allows modificat...

Page 14: ...ery Carry out the remote control acknowledgement procedure Check the lack of mains voltage The flashing light only functions for 4 seconds and the gate moves slowly only with a 12V optional battery fi...

Page 15: ...ce within the times established by the installer the manufacturer and by current legislation All installation maintenance repairs and cleaning operations must be documented This documentation must be...

Page 16: ...MO SEGNATE MN ITALY T el 39 0376 616 638 Fax 39 0376 629 456 http www bame it http www delma it Unit locale Via Enrico Berlinguer 6 63844 GROTTAZZOLINA FM ITALY T el 39 0734 633 533 Fax 39 0734 636 89...

Reviews: