GENERAL DIAGRAM OF SETTINGS AND CONNECTIONS
NOTE: The control unit is supplied with a trimmer to adjust the force of the motors set on maximum value
(100%).
Maintain this setting, which facilitates installation in difficult conditions (worn-out or not lubricated hinges, stress
points etc.) Afterwards, reduce the force to obtain an operator movement that is slower and requires less force.
After
having adjusted the force the learning procedure must be repeated.
Feeler
Signal
Ground
FUSE 10 A
(battery)
Pushbutton
P2/RADIO
Pushbutton
P1/SET
R
F
M
O
D
U
L
E
FUSE 1 A
(Mains)
Transformer 230/12VAC
for motors 12VDC
(Transformer 230/20VAC
for motors 24VDC)
MOTOR
12 VDC max 50W
(24VDC max 60W)
PHO and STP inputs – must
be bridged if not used
Flashing
light 12V 10W
Photocells
TX
RX
Emergency battery
12VDC (max 7Ah)
230 VAC (MAINS)
Install differential
thermo-magnetic
circuit breaker 6A
(IC=30mA)
ELU / LCU
Pushbutton
OPEN
Closing limit switch motor 1
Opening limit switch motor 1
Closing limit switch motor 2
Opening limit switch motor 2
Solar Panel
FUSE 2 A
(accessory)
ON
OFF
SIGNALLING LED
Gate Open LED
12 VDC max
3W
FORCE /
SPEED
STANDBY
TIME
SWING
DELAY
OBSTACLE
SENSITIVITY
Pedestrian
opening
STOP
Open/
Step by Step
External 12V
Power supply
DIP SWITCHES
Electric
lock 12V
max 15W
- [] +
NC C NO
- [] +