Item Control/Feature
Icon Description
15
Mini-SAS port B (Slot 2/
Port 2)
Back-end expansion port B
16
Mini-SAS port A (Slot 2/
Port 1)
Back-end expansion port A
SCv2080 Storage System Storage Controller with Front-End SAS Ports
The following figure shows the features and indicators on a storage controller with front-end SAS ports.
Figure 7. SCv2080 Storage System Storage Controller with Four 12 Gb Front-End SAS Ports
Item Control/Feature
Icon Description
1
Battery status indicator
•
Blinking green (on 0.5 sec. / off 1.5 sec.)
: Battery heartbeat
•
Fast blinking green (on 0.5 sec. / off 0.5 sec.)
: Battery is
charging
•
Steady green
: Battery is ready
2
Battery fault indicator
•
Off
: No faults
•
Blinking amber
: Correctable fault detected
•
Steady amber
: Uncorrectable fault detected; replace battery
3
MGMT port (Slot 3/Port
1)
—
Ethernet/iSCSI port that is typically used for storage system
management and access to the BMC
NOTE: To use the MGMT port as an iSCSI port for
replication to another Storage Center, a Flex Port license
and replication license are required. To use the MGMT port
as a front-end connection to host servers, a Flex Port
license is required.
4
REPL port (Slot 3/Port 2) —
Ethernet/iSCSI port that is typically used for replication to
another Storage Center
NOTE: To use the RELP port as a front-end connection to
host servers, a Flex Port license is required.
5
SAS activity indicators
—
There are four SAS PHYs per SAS port.
•
Off
: SAS PHY is not connected
•
Steady green
: SAS PHY is connected, but not active
•
Blinking green
: SAS PHY is not connected nor active
6
Storage controller
module status
On
: Storage controller completed POST
About the SCv2080 Storage System
15