Troubleshooting VLT
To help troubleshoot different VLT issues that may occur, use the following information.
NOTE:
For information on VLT Failure mode timing and its impact, contact your Dell Networking representative.
Table 108. Troubleshooting VLT
Description
Behavior at Peer Up
Behavior During Run Time
Action to Take
Bandwidth monitoring
A syslog error message and an
SNMP trap is generated when
the VLTi bandwidth usage goes
above the 80% threshold and
when it drops below 80%.
A syslog error message and an
SNMP trap is generated when
the VLTi bandwidth usage goes
above its threshold.
Depending on the traffic that is
received, the traffic can be
offloaded inVLTi.
Domain ID mismatch
The VLT peer does not boot up.
The VLTi is forced to a down
state.
A syslog error message and an
SNMP trap are generated.
The VLT peer does not boot up.
The VLTi is forced to a down
state.
A syslog error message and an
SNMP trap are generated.
Verify the domain ID matches on
both VLT peers.
Dell Networking OS Version
mismatch
A syslog error message is
generated.
A syslog error message is
generated.
Follow the correct upgrade
procedure for the unit with the
mismatched Dell Networking OS
version.
Remote VLT port channel status N/A
N/A
Use the
show vlt detail
and
show vlt brief
commands to view the VLT port
channel status information.
Spanning tree mismatch at
global level
All VLT port channels go down
on both VLT peers. A syslog
error message is generated.
No traffic is passed on the port
channels.
A one-time informational syslog
message is generated.
During run time, a loop may
occur as long as the mismatch
lasts.
To resolve, enable RSTP on both
VLT peers.
Spanning tree mismatch at port
level
A syslog error message is
generated.
A one-time informational syslog
message is generated.
Correct the spanning tree
configuration on the ports.
System MAC mismatch
A syslog error message and an
SNMP trap are generated.
A syslog error message and an
SNMP trap are generated.
Verify that the unit ID of VLT
peers is not the same on both
units and that the MAC address
is the same on both units.
Unit ID mismatch
The VLT peer does not boot up.
The VLTi is forced to a down
state.
A syslog error message is
generated.
The VLT peer does not boot up.
The VLTi is forced to a down
state.
A syslog error message is
generated.
Verify the unit ID is correct on
both VLT peers. Unit ID numbers
must be sequential on peer units;
for example, if Peer 1 is unit ID
“0”, Peer 2 unit ID must be “1’.
Version ID mismatch
A syslog error message and an
SNMP trap are generated.
A syslog error message and an
SNMP trap are generated.
Verify the Dell Networking OS
software versions on the VLT
peers is compatible. For more
Virtual Link Trunking (VLT)
1025
Summary of Contents for S4048T-ON
Page 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Page 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Page 251: ...Dell Control Plane Policing CoPP 251 ...
Page 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Page 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Page 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Page 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Page 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Page 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Page 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Page 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...