Error Code Message Information
CPU0204
Message
CPU <
number
> <
name
> voltage is outside of range.
LCD Message CPU <
number
> <
name
> voltage is outside of range. Re-seat CPU.
Details
Voltages outside the allowable range may damage electrical components or may cause
the system to shutdown.
Action
1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see
.
CPU0700
Message
CPU <
number
> initialization error detected.
LCD Message
CPU <
number
> initialization error detected. Power cycle system.
Details
System BIOS was unable to initialize the processor.
Action
1. Turn off the system and remove input power for one minute.
2. Ensure the processor is seated correctly.
3. Reapply input power and turn on the system.
4. If the issue persists, see
CPU0701
Message
CPU <
number
> protocol error detected.
LCD Message CPU <
number
> protocol error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the exception is external
to the processor.
Action
1. Check system and operating system logs for exceptions. If no exceptions are
found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn on the system.
5. If the issue persists, see
.
CPU0702
Message
CPU bus parity error detected.
LCD Message CPU bus parity error detected. Power cycle system.
Details
System event log and operating system logs may indicate that the exception is external
to the processor.
Action
1. Check system and operating system logs for exceptions. If no exceptions are
found, continue.
2. Turn off the system and remove input power for one minute.
3. Ensure the processor is seated correctly.