28
About Your System
E1620
Power Supply
# (### W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."
E1624
Lost power
supply
redundancy.
Check PSU
cables.
The power supply
subsystem is no longer
redundant. If the remaining
power supply fails, the
system will shut down.
See "Troubleshooting
Power Supplies."
E1626
Power Supply
Mismatch.
PSU1 = ### W,
PSU2 = ### W.
The power supplies in the
system are not the same
wattage.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system’s
Getting
Started Guide
.
E1629
Power
required >
PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
E1710
I/O channel
check error.
Review &
clear SEL.
The system BIOS has
reported an I/O channel
check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help."
Table 1-1.
LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions