Table 5-4. Descriptions and Corrective Actions (continued)
6
,
continued
For Problems with Writing Data:
If the problem occurred while the drive was writing data to the tape, and if you know the
volume serial number (located on the cartridge label) of the tape cartridge loaded in the drive
when the problem occurred, retry the operation with a different cartridge:
If the problem occurs with multiple tape cartridges or if you do not know the tape cartridge's
volume serial number, run the tape drive diagnostics (see Function Code 1 in “Selecting a
Diagnostic or Maintenance Function” on page 5-1):
v
If the diagnostics fail, contact Dell technical support.
v
If the diagnostics succeed, run the Test Head diagnostic (see Function Code H in “Selecting
a Diagnostic or Maintenance Function” on page 5-1).
– If the Test Head diagnostic fails, contact Dell technical support.
– If the Test Head diagnostic succeeds, replace the cartridges that caused the problem.
The error code clears when you remove the tape cartridge or place the drive in maintenance
mode.
If the problem occurred while the drive was reading data from the tape, and if you know the
volume serial number of the tape cartridge, perform one of the following procedures:
v
If another drive is available, insert the cartridge into the other drive and retry the
operation:
– If the operation fails, discard the defective cartridge.
– If the operation succeeds, insert a scratch cartridge into the first drive and run the tape
drive diagnostics (see Function Code 1 in “Selecting a Diagnostic or Maintenance
Function” on page 5-1):
- If the diagnostics fail, contact Dell technical support.
- If the diagnostics succeed, the error was temporary.
v
If another drive is not available, insert a scratch cartridge into the drive and run the tape
drive diagnostics (see Function Code 1 in “Selecting a Diagnostic or Maintenance
Function” on page 5-1)
– If the diagnostics fail, contact Dell technical support.
– If the diagnostics succeed, discard the cartridge
For Problems with Reading Data:
If the problem occurs with multiple tape cartridges or if you do not know the tape cartridge's
volume serial number, run the tape drive diagnostics (see Function Code 1 in “Selecting a
Diagnostic or Maintenance Function” on page 5-1):
v
If the diagnostics fail, contact Dell technical support.
v
If the diagnostics succeed, run the Test Head diagnostic (see Function Code H in “Selecting
a Diagnostic or Maintenance Function” on page 5-1).
– If the Test Head diagnostic fails, contact Dell technical support.
– If the Test Head diagnostic succeeds, replace the cartridges that caused the problem.
The error code clears when you remove the tape cartridge or place the drive in maintenance
mode.
7
A high probability of media error. The tape drive determined that an error occurred because
of a faulty tape cartridge. Try another tape cartridge. If the problem occurs with multiple tape
cartridges, see “Resolving Media-Related Problems” on page 5-16. This error will also appear
if you are loading an expired cleaner cartridge.
The error code clears when you remove the tape cartridge or place the drive in maintenance
mode.
5-12
Dell PowerVault LTO Tape Drive User's Guide
Summary of Contents for PowerVault LTO5-140
Page 1: ...Dell PowerVault LTO Tape User s Guide User s Guide ...
Page 4: ...iv Dell PowerVault LTO Tape Drive User s Guide ...
Page 6: ...vi Dell PowerVault LTO Tape Drive User s Guide ...
Page 8: ...viii Dell PowerVault LTO Tape Drive User s Guide ...
Page 16: ...1 8 Dell PowerVault LTO Tape Drive User s Guide ...
Page 26: ...2 10 Dell PowerVault LTO Tape Drive User s Guide ...
Page 34: ...3 8 Dell PowerVault LTO Tape Drive User s Guide ...
Page 36: ...4 2 Dell PowerVault LTO Tape Drive User s Guide ...
Page 80: ...8 16 Dell PowerVault LTO Tape Drive User s Guide ...
Page 82: ...A 2 Dell PowerVault LTO Tape Drive User s Guide ...